Shouxin's production lead time — the period from order confirmation and payment receipt to completion of manufacturing — is generally 1 to 2 weeks.Established (founded) in1970year;Approaching 60With years of manufacturing experience, the company invests a large amount of funds in technical innovation research every year to ensure the uniformity, stability and progressiveness of the instrument. Enable the instrument to bring more accurate scientific research results to users,SHELLABBrand isSheldonThe company's trademark. The company sells globally. We specialize in producing anaerobic incubators and low oxygen incubatorslarge capacityCO2Incubatorhigh-temperature sterilizationCO2Incubator, Microbial Incubator, Biochemical Incubator, Oven, Vacuum Drying OvenprogrammingA box company mainly engaged in drying ovens and pearl bath ovens.
The new BACTRON 400HP-2 anaerobic incubator, launched by SHELDON from the United States in January 2024, features oxygen monitoring display, humidity monitoring display, temperature monitoring display, multiple HEPA high-efficiency filters, and box cover opening; More suitable for drug development and vaccine companies. The specific performance characteristics are as follows
Box structure:The whole machine is made of stainless steel body and hard organic glass sealing, which is more sturdy and durable than general models without stainless steel body, and has a wide field of view.Can open the cover plateConvenient for operators to place the required small instruments and extremely easy to clean and disinfect.
control panel:10.1-inch color touch screen, real-time display of the current operating status of the anaerobic workstation; Historical data can be recorded and stored; The screen can be password locked to prevent the set values from being changed.
Oxygen display:Real time monitoring and display of oxygen concentration value (PPM) on the touch screenAnd real-time display of temperature and humidity values.
HEPA high-efficiency filtration: Outer side of the boxPrepare two HEPA filters(99.7%@0.3um)Filter the intake nitrogen and mixed gas; The interior of the box is also equipped withHigh efficiency filter screen,Can filter 99.7% @ 0.3um, allowing the workspace to reachClass 1 (ISO 3) grade
Bare handed cuff design:Comfortable to wear; The cuff is sealed around the operator's arm,Allow naked hands to conduct experimental operations inside the box;Ergonomic arm port design eliminates the problems of poor accuracy, inflexible operation, and obvious restraint in traditional glove designs. Improved comfort and work efficiency.
Independent training room:Independent cultivation room and operating chamber are mutually independent, located on the back of the operating room, with45Independent cultivation space for promotion (can be placed)300A culture dish,The cultivation effect is very ideal;To avoid fluctuations in the cultivation temperature caused by external temperatures in integrated design, and to avoid the discomfort of stuffiness and sweating in the operator's hands caused by integrated design;In addition, it increases the comfort of the operator; Provide users with a wider visual space.
Culture Roomtemperature range:room temperature+5℃~70℃The temperature range is wider, providing users with temperature optionsWhen users' research fields require the cultivation of high-temperature thermophilic cells or bacteria in the future, this temperature range solves their concerns.
Sample Transfer RoomOperation method:The sample transfer chamber has a large space and is equipped with a very flexible sliding tray, which can facilitate the transfer of samples from the transfer chamber to the workbench. Transfer Room14Volume increaseplaceable78Block standard culture dish or large capacity triangular flask.The sample transfer chamber can be deoxygenated manually or automatically, and automatic deoxygenation can be setNumber of times(3Next time -9time)It can be automatically completed with just one button press.60Quickly circulate and release oxygen in seconds.
Operating room and sleeve exhaust control:Press the automatic button in the operating room once to automatically exhaust oxygen to reach anaerobic environment; Quickly and conveniently transform the operating room into an anaerobic environment. No need to wait for depressurization or open the operating room door to exhaust oxygen, saving time and safety. The sleeve only needs to use a foot pedal switch once to automatically replace the gas; Establish an anaerobic environment for sleeves; Eliminate tedious exchange actions, all gases in the program pass throughHEPAPurification and filtration.
The operating room is equipped with a constant pressure system: Maintenance in the operating room0.5The positive pressure of inches of water column pressure will automatically eliminate excess pressure if it exceeds the standard pressure value, ensuring the comfort of the operator and stable pressure in the anaerobic environment.
Performance parameters:
1. Working chamber volume:≥560L;Culture Room:≥45L. Transmitting cavity:≥26L
▲ 2Training RoomWendegreeRoom temperature+5 ℃ -70 ℃
3. Uniformity of temperature in the cultivation room: ± 0.5 ℃
4. Dimensions (cm):≥162ⅹ82ⅹ76
5. Size of transmission room (cm):≥40ⅹ25ⅹ29
6. Operating room size (cm):≥110ⅹ71ⅹ75
▲ 7.Number of culture dishes that can be accommodated in an independent culture room: 400;While ensuring operational comfort, the entire operating room can accommodate more samples or experimental equipment such as triangular flasks required for operation.
Note: Anaerobic incubators require two types of gases, one is a mixed gas( Proportion: 5% Hydrogen, 5% Carbon dioxide, 90% The other type is 100% pure nitrogen. Avoid using 10Hydrogen gas is prone to ignition and poses a danger during operation. So Bactron anaerobic workstation uses 5%Anaerobic effect can be achieved with hydrogen gas. In addition, the anaerobic workstation has an automatic switching system that can automatically switch between two gases, which can save relatively expensive mixed gases and reduce operating costs.