Welcome Customer !
instrumentb2bDo you know how to test formaldehyde emissions in a 1m ³ climate chamber formaldehyde testing chamber

The newly revised GB18580-2017 "Formaldehyde Release from Indoor Decoration Materials, Artificial Boards and Their Products" will be implemented this year, which means that the 1m3 climate chamber method will become the * method for furniture and flooring manufacturers to detect formaldehyde release.

1m ³ climate chamber formaldehyde testing chamberTest method:

*According to GB18580-2017, indoor decoration materials - Determination of formaldehyde emissions from artificial boards and their products (one cubic meter climate chamber method). Formaldehyde is released from the sample and mixed with the air inside the box. The air inside the box is periodically extracted and passed through an absorption bottle containing distilled water. All formaldehyde in the air is dissolved in the water; Measure the amount of formaldehyde in the absorption solution and the volume of extracted air, calculate the amount of formaldehyde per cubic meter of air, expressed in mg/m3. Extraction is periodic until the formaldehyde concentration in the air inside the climate chamber reaches a stable state.

Secondly, the dimensions of the specimen are length=(500 ± 5) mm and width b=(500 ± 5) mm. There are two specimens with a surface area of 1m2. When the length and width of the specimens are smaller than the required dimensions, it is allowed to use a method that does not affect the measurement results to assemble them.

model

SY11-N02

SY11-N1

Nominal internal volume (liters)

225(1±2%)

1000(1±2%)

internal dimensions

(mm)

W

550

850

D

600

1080

H

680

1100

external dimensions

(mm)

W

1100

1460

D

796

1285

H

1520

1572

sex

can

temperature range

15~30 ℃

humidity range

35~70 % RH

temperature deviation

≤ ±0.5 ℃

Humidity deviation

≤ ± 2% RH

Temperature Uniformity

≤±0.8 ℃

Humidity uniformity

≤ ±2 % RH

temperature fluctuation

≤ ±0.5℃

Humidity fluctuation

≤ ± 2% RH

Ventilation rate

0-1.5Times/hour

sealing performance

The air leakage rate inside the cabin is less than 5%. If the gas supply rate or pressure exceeds 1kpa, the gas leakage rate is less than 0.5% of the cabin capacity per minute

Central wind speed

0.1-1.0m/s(Continuously adjustable)

Relative positive pressure

10±5pa

spike recovery rate

>80%

Background value

Formaldehyde: ≤ 0.006mg/m3

Temperature control method

Indirect temperature control method for water circulation

Humidity control method

Dual directional adjustment method for dry gas and moisture ratio

material

shell

Q23Cold rolled steel plate 1.5mm, surface electrostatic spraying, white

inner box

SUS304Mirror stainless steel 1.5mm (8k mirror)

adiabatic

High density polyurethane foam+XPS

seal

Silicone (food grade), polytetrafluoroethylene

Operation control

monitor

7Inch color touch screen, resolution 800x480, remote control (optional)

Automatically record projects

Temperature, humidity, pressure (optional), flow rate (optional), operating time, fault record

Control method

Temperature control: proportional, integral, derivative (P.I.D); System control: PLC+HMI

resolution

Temperature: 0.1 ℃; Humidity: 0.1% RH

communication interface

1One USB-A, one USB-B, one RS232, one RS485, and one RJ-45 (optional)

Rough storage and recording function

Memory, USB flash drive, SD card

Supplement water quality and cycle

Distilled water; >30 days (continuous operation)

power supply

AC380(1 ± 10%) V (50 ± 0.5) Hz three-phase four wire+protective grounding

Installed capacity (Kw)

2.5

3.0

Weight (Kg)

280

320

Noise (dB)

≤ 60dB

System protection

High and low pressure protection, overcurrent protection of refrigeration system; Overtemperature protection; Motor overcurrent protection; Water shortage protection; Power supply under phase, phase sequence protection, etc.

Latest News