Precautions for Data Collection of Handheld Stacking Measuring Instrument
Date: 2023-11-09Read: 0

1、Handheld Stacking Measuring InstrumentLong press the power button 3 Second, the status indicator light is green and constantly on. Wait for the laser head to start rotating, and the device will start successfully. Please hold the scanner steadily and keep the laser head vertically upward.

2Short press the power button to activate the data acquisition function, and the status indicator light will turn green and flash. After starting the recording, the scanner needs to be allowed to stand still for at least 1 Start the exercise collection in minutes, and do not hold it in your hands when standing still. It must be placed steadily on a fixed surface such as the ground or table.

3During the data collection process, please keep the scanner in front of your body, aligned with your walking direction, and with the laser head facing upwards.

4Short press the power button, the device ends data collection, and the status indicator light returns to a steady state; Then press and hold the power button to turn off the device. At this point, the status indicator light will turn off and the laser head will stop rotating.

5It is recommended that users shut down and restart after completing a single data collection before proceeding to the next data collection.

6In principle, it is not required to follow a closed-loop path, but to ensure data accuracy, it is recommended that users follow a complete closed-loop route when conditions permit.

7The data collection process should be smooth, avoiding violent shaking, and the laser head should not be lowered.

8、Handheld Stacking Measuring InstrumentThe single data collection time should be greater than 60 In seconds.

9Maintain the distance between the scanner and the object being measured0.4mAvoid close proximity of the laser head0.4mTurn towards the wall.

10、Handheld Stacking Measuring InstrumentDuring the data collection process, it is necessary to maintain continuity and ensure a certain degree of overlap.