Welcome Customer !

Membership

Help

Zhengzhou Junda Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Download Materials>Cleanliness level standard
Download

Zhengzhou Junda Instrument Co., Ltd

  • E-mail

    13526877955@139.com

  • Phone

    13526877955

  • Address

    1-818 Xinyuan Duhui Plaza, Daxue South Road, Zhengzhou City

Contact Now
Cleanliness level standard
Date: 2013-06-18Read: 0

Cleanliness level standard

ISO 14644Classify the air cleanliness level in clean rooms (zones) and related controlled environments based on the concentration of suspended particles, and only consider the particle size limit (lower limit)0.1um~5.0umA particle swarm with cumulative distribution within the range.

According to particle size, it can be divided into regular particles(0.1um~5.0um)Ultra fine particles (<)0.1um)And macro particles (>5.0um).

Classification standards for air cleanliness:ISO14644-1(Standard)

Air cleanliness level(N)

Maximum concentration limit for particles larger than or equal to the specified particle size (individual)/Particles per cubic meter of air

0.1 um

0.2 um

0.3 um

0.5um

1um

5 um

ISO Class 1

10

2

ISO Class 2

100

24

10

4

ISO Class 3

1 000

237

102

35

8

ISO Class 4

10 000

2 370

1 020

352

83

ISO Class 5

100 000

23 700

10 200

3 520

832

29

ISO Class 6

1 000 000

237 000

102 000

35 200

8 320

293

ISO Class 7

352 000

83 200

2 930

ISO Class 8

3 520 000

832 000

29 300

ISO Class 9

35 200 000

8 320 000

293 000

Note: Due to the uncertainty involved in the measurement process, it is required to use no more than three valid concentration numbers to determine the level.

Classification standards for air cleanliness:GB/T16292-1996(Chinese Standard)

Particle size, numerical cleanliness level

Maximum allowable number of dust particles/cubic meter

Maximum allowable number of microorganisms

≥0.5um

≥5um

airborne microbe/cubic meter

settling microorganism/dish

100 level

3,500

0

5

1

10,000level

350,000

2,000

100

3

100,000level

3,500,000

20,000

500

10

300,000level

10,500,000

60,000

—

15

the United Kingdom 5295 Classification of Standard Cleanrooms and Air Purification Devices:

Air cleanliness level(N)

Maximum concentration limit for particles larger than or equal to the specified particle size (individual)/Particles per cubic meter of air

0.3um

0.5um

5um

10um

25 um

C

100

35

0

D

1000

350

0

E

10000

3500

0

F

3500

0

G

100000

35000

200

0

H

35000

200

0

J

350000

2000

450

0

K

3500000

20000

4500

500

L

200000

45000

5000

M

450000

50000

Comparison of various standards:

U.S. federal

U.S. federal

British Standard

Australian Standards

French standards

German Standard

standard

Japanese standards

standard 209D

standard 209E

BS5295

AS1386

AFNORX44101

VDI2083

14644-1

JACA24

1

1

—

0

2

2

1

M1.5

C

0.035

—

1

3

3

10

M2.5

D

0.35

—

2

4

4

100

M3.5

E

3.5

4000

3

5

5

1000

M4.5

G

35

—

4

6

6

10000

M5.5

J

350

400000

5

7

7

100000

M6.5

K

3500

4000000

6

8

8

M

7

9

—