1Determination of arginine in cefotaxime for injection
Method: CHP2010 Part II (chromatographic column requirement: dihydroxypropyl bonded silica gel column)
Chromatography column: LiChrosphere Dior 5um 250 * 4.0mm (item number: 1.50836.0001, card sleeve 1.51486.0001 required)
Mobile phase: Dissolve 1.15g of ammonium dihydrogen phosphate in 1000ml of volumetric solution (adjust pH to 2.0 with phosphoric acid) - acetonitrile (25:75)
Flow rate: 1ml/min
Injection volume: 20ul
Detection wavelength: 206nm
Column temperature: 35 ℃
Reference map:
2CyclosporineHPLCanalyze
Method: According to relevant standards such as EP and CHP, we would like to express our gratitude to the provincial drug testing institute for providing
Column: LiChrospher RP-18e 5um 250 * 4.0mm
(Column information: Order 1, item number: 1.50838.0001, card sleeve 1.51486.0001 is required;);
Order 2, item number: 1.01886.0008, no card sleeve required. )
Mobile phase: A-H2O (0.05MH3PO4) B-THF Gradient: A: B=55:45
Detection: 220nm
Column temperature: 75 ℃
Flow rate: 1.2mL/min
Injection volume: 10ul
3Polycyclic aromatic hydrocarbonsHPLCpillar
Application: GB/T 22509-2008 Determination of benzo (a) pyrene in animal and vegetable oils and fats Reverse phase liquid chromatography method
Chromatographic column: National standard column, Lichrospher PAH 5um 250 * 4.0mm (item number: 1.50149.0001, card sleeve 1.51486.0001 required)
4Soybean phospholipidsHPLCanalyze
Application: GB/T 21493-2008 Determination of Phosphatidylcholine, Phosphatidylethanolamine, and Phosphatidylinositol in Soybean Phospholipids
Chromatography column: National standard column, Lichrospher Si 60 5um 250 * 4.0mm (item number: 1.50830.0001, card sleeve 1.51486.0001 is required)