Programmable constant temperature and humidity controller
fuck
make, do, create, compose, write, etc.
hand
volume
U-700/560-TH
eye record
1 Safety instructions(Attention)matter···1
2.1 Basic operational flowchart··2
2.2 parameter(PARAMETER)Setting method··3
2.2.1Validity of setting keys and values···4
2.2.2Set value input method···4
3. Operation status setting···5
3.2.1fixed value(FIX)run 第 1 Stop screen···6
3.2.2fixed value(FIX)run 第 1 runtime screen···8
3.2.3fixed value(FIX)run 第 2 runtime screen···9
3.2.4fixed value(FIX)run 第 3 runtime screen···10
3.2.5fixed value(FIX)run Stop screen···11
3.3.1program(PROGRAM)run 第 1 Stop screen···12
3.3.2program(PROGRAM)run 第 1 runtime screen···13
3.3.3program(PROGRAM)run 第 2 runtime screen···14
3.3.4program(PROGRAM)run 第 3 runtime screen···15
3.3.5program(PROGRAM)run Stop screen···16
4. Run related operation settings···17
5. Program group configuration···19
5.1 Program editing settings··20
5.6 Experiment name setting··28
6. Historical Curve and Storage Devices···29
7 Screen display settings···30
7.1 Screen display settings··30
7.2 DIView fault occurrence records··31
1 Safety instructions(Attention)matter
Thank you very much for purchasing our constant temperature and humidity program controller.
This operating manual describes the operating methods of this product as follows.
Precautions in this operating manual |
(A)Please provide this operating manual to the ultimate user and keep it in a readily accessible location for easy reference.
(B)Please read this operating manual carefully before using this product.
(C)This operating manual provides a detailed explanation of the various functions of the product and does not guarantee anything outside of the operating manual.
(D)Without permission, it is not allowed to edit, copy, or use part or all of the contents of this operating manual.
(E)The content of this operating manual may be changed at will without prior notice or announcement.
(F)Although this operating manual has been written in its entirety to the best of our ability, there may be some shortcomings, typos, or omissions in the content. If any are found, please contact usThank you very much for contacting the purchasing department or our company.
The safety and modification of this product(change)Precautions |
(A)To ensure the maintenance and safety of this product and the system connected to it, please carefully read the relevant safety precautions in this operating manual(instruction)Use this product after the event.
(B)Our company shall not be responsible for any losses caused by the use, placement, or neglect of the instructions in this operating manual.
(C)In order to ensure the maintenance and safety of this product and the system connected to it, if additional protective devices or safety circuits need to be installed, please be sure to install them on the outside of this product. It is strictly prohibited to modify the interior of this product(change)Or add.
(D)Please do not disassemble, repair or modify without authorization, as it may cause electric shock, fire or malfunction during work.
(E)When replacing parts or consumables of this product, please be sure to obtain them from our company's sales department.
(F)Please do not let moisture flow into this product as it may cause malfunctions.
(G)Please do not impact this product as it may cause damage or malfunction.
This product is exempt from liability |
(A)Except for the content specified in our company's quality assurance conditions, we do not guarantee or assume any responsibility.
(B)During the use of this product, the company shall not be held responsible for any direct or indirect damages suffered by users or third parties due to unforeseeable defects or natural disasters.
2 Operation and Setting
2.1 Basic operational flowchart
?After installing the product, plug in the power and the startup progress screen will be displayed.
? The startup screen takes approximately time15In seconds.
splash screen
Main screen

2.2 parameter(PARAMETER)Setting method
①Digital input box
②Name the program experiment andDIInput box for fault name
③Indication when exceeding the set range
|
Touch screen lock(KEY LOCK)unlock
? The 'locked' status is“ON(lock)”When unable to input the set value, please change the "locked" status to“OFF (Unlock)”Enter the status later. ? Please refer to the detailed setting method[4.Run operation settings] |
2.2.1Validity of setting keys and values
? This product uses a prompt sound to confirm whether the input value is valid when clicking the set value input button.
? “Bi”:When clicking the basic setting button or when the input setting value is normal
? “BBB”:When the set value entered in the input box exceeds the input range
|
Operation precautions ? Please do not use sharp objects when clicking on the basic settings button and setting value input box(Pencil, etc)Don't hit too hard either. Possible malfunction or damage to the touch screen. |
2.2.2Set value input method
? Function and description of setting value input box
① Display'parameter(PARAMETER)'.
② Display“set the scope'.
③ It is the 'Set Value Display Window''When it exceeds the set range, a fault reminder message will be displayed(Input error).
④ Use this key when stopping input and returning to the original screen.
⑤ After storing the input value, return to the original screen.
⑥ Used when entering decimal points.
⑦ Input(+/-)When using symbols.
⑧ Used when modifying input values, input values can be deleted word by word.
⑨ Used when deleting all input values.
3. Operation status setting
3.1 Main painting
serial number |
Instruction content |
Content description |
① |
Monitoring screen |
Switch to the running screen. |
② |
Curve display |
Switch to curve representation and curve storageUSBStorage devices and exported curves. |
③ |
Operation settings |
Switch to the settings screen for functions and operating modes. |
④ |
Program settings |
Switch to the program settings main screen. |
⑤ |
reserve set |
Switch to the screen for setting the current time and appointment time. |
⑥ |
visual setting |
Use the prompt sound to display the settings screen. |
3.2 fixed value(FIX)run
3.2.1fixed value(FIX)run 第 1 Stop screen
?[3.1Main screen]Select the monitoring screen in the middle to switch to the "fixed value(FIX)run 第1Operation screen ".
?[4.Run operation settings]The selected running mode is“fixed value(FIX)”.
[image3-2]fixed value(FIX)run 第 1 Stop screen
?The input and operation implementation method of temperature setting value is as follows.
[image3-3]Temperature setting value input box
?When entering the temperature setting value, click the red button at the top left to activate it[image3-3Temperature setting value input box]The temperature setting value input box in.
? The input and operation implementation method of humidity setting value is as follows.
[image3-4]Humidity setting value input box
? When entering the humidity setting value, click the blue button at the bottom left to activate it[image3-4Humidity setting value input box]The humidity setting value input box in.
? Temperature input completed·After setting the humidity value, select the one at the bottom right(run)Key, can execute fixed value operation.
3.2.2fixed value(FIX)run 第 1 runtime screen
[image3-5]fixed value(FIX)run 第 1 runtime screen
① Indicates the current temperature setting value.
② Indicates the current temperature.
③ Indicates the current humidity.
④ Indicates the current humidity setting value.
⑤ Indicate the current date/Time, click to turn offLCDscene
⑥ Switch from the current screen to the next screen.
⑦ At the current set temperature value, it can be executed(TUNING ON)Or release(TUNING OFF)manual adjustment(AUTO TUNING).
? can pass through[Installation Manual]of[PIDgroup]Set whether to use adjustment keys.
⑧ With the current set humidity value, it can be executed(TUNING ON)Or release(TUNING OFF)manual adjustment(AUTO TUNING).
? can pass through[Installation Manual]of[PIDgroup]Set whether to use adjustment keys.
⑨ Lighting key.
?click(lighting)key,The pre-set relay will activate. The relay points to the lighting.
⑩ The key to stop the constant value operation
? Displayed under the fixed value stop screen(run)The key.
※ Under the fixed value operation stop screen ⑨,⑩ The key is in an inactive state.
3.2.3fixed value(FIX)run 第 2 runtime screen
?Display screen of command values, set values, control output values, and status light action status.
[image3-6]fixed value(FIX)run 第 2 runtime screen
①ONStatus is indicated in red,OFFThe status is represented in dark gray.
②Indicate the currently applicablePID ZONEThe number.
③ Indicates the current temperature control output.
④ Indicates the current humidity control output.
⑤ Indicates the duration of running at a constant value.
3.2.4fixed value(FIX)run 第 3 runtime screen
? The temperature is displayed on the left side of the screen·The set value and control output value of humidity.
? Set whether to display data by checking the box.
[image3-7]fixed value(FIX)run 第 3 runtime screen
① Indicate the command value, set value, and control output value of the current temperature and humidity.
② enterUSBStorage device screen.
③ Delete the current experimental curve.
④ The timeline moves left and right.
? The sampling time is30In seconds, it can be stored approximately56Oh my god.
3.2.5fixed value(FIX)run Stop screen
?[4.Run related operation settings]After the set time is full, the operation will end, as shown in the following figure, and it will display“Fixed value end”At the same time, terminate the fixed value operation with a prompt message.
? If clicking during operation“停止”If the key is forced to terminate, the prompt message will not appear on the screen.
? When there is a message indicating the termination of the operation, touch that part of the screen and the message will disappear.
? The same applies when the program terminates
[image3-8]fixed value(FIX)run Stop screen
3.3 program(PROGRAM)run
3.3.1program(PROGRAM)run 第 1 Stop screen
?[3.1Main screen]When selecting 'Monitoring Screen', you can switch to 'Program'(PROGRAM)run 第1Operation screen ".
?[4.Run related operation settings]Select the running mode as“program”.
?Please refer to the program setting method[5.1Program settings].
?[image3-9program(PROGRAM)第 1 Stop screen]Click on the bottom right corner in the middle(run)The key will switch to[image3-10program(PROGRAM)第 1 runtime screen].
[image3-9]program(PROGRAM)第 1 Stop screen
※Precautions for program operation:
?If the number of segments is displayed as0If so, it will not run.
3.3.2program(PROGRAM)run 第 1 runtime screen
[image3-10]program(PROGRAM)第 1 runtime screen
① Indicates the current running segment temperature setting value.
② Indicates the current temperature.
③ Indicates the current humidity.
④ Indicates the current humidity setting value for the running segment.
⑤ Maintain(HOLD ON)Or release(HOLD OFF)Current temperature and humidity setting values.
⑥ Terminate the current ongoing segment and force a jump to the next segment.
⑦ At the current set temperature value, it can be executed(TUNING ON)Or release(TUNING OFF)Manually adjust.
⑧ With the current set humidity value, it can be executed(TUNING ON)Or release(TUNING OFF)Manually adjust.
⑨ Lighting key.
?click(lighting)key,The pre-set relay will activate. The relay points to the lighting.
⑩ The key to stop the constant value operation.
? Display in the fixed value stop screen(run)The key.
※ In the program running stop screen ⑤~⑧ The key is in an inactive state.
3.3.3program(PROGRAM)run 第 2 runtime screen
?Screen displaying command values, set values, control output values, and status light operation status
[image3-11]program(PROGRAM)第 2 runtime screen
①ONThe status is represented in red,OFFThe status is represented in dark gray.
② Indicate the current running program number and segment number.
③ Represents a program loop.
?[Group cycle: 000/000]The preceding number represents the number of cycles executed, while the following number represents the set number
Number of cycles.
④ Indicate the currently applicablePID ZONENumber.
⑤ Indicates a partial loop state.
?[SEG]number of cycles: 00/00]The preceding number represents the number of cycles executed, while the following number represents the set number of cycles.
⑥ Indicates the duration of the current segment and the set time.
?[SEG]time: 000H00M/000H00M]The preceding time represents the duration of the segment,The following time indicates[5.1Program group mode setting]The time set in.
⑦ Indicates the running time of the program.
3.3.4program(PROGRAM)run 第 3 runtime screen
[image3-7]fixed value(FIX)run 第 3 runtime screen
① Indicate the command value, set value, and control output value of the current temperature and humidity.
② enterUSBStorage device screen.
③ Delete the current experimental curve.
④ The timeline moves left and right.
? The sampling time is30In seconds, it can be stored approximately56Oh my god.
3.3.5program(PROGRAM)run Stop screen
? After the set interval of all segments stored in the mode is terminated, the prompt message "Program End" will be displayed as shown in the figure, and then the program will end.
? Click during operation“停止”If the key is forced to terminate, there will be no prompt message on the screen.
? If there is a message indicating the termination of the operation, touch that part of the screen and the message will disappear.
? The same applies when the fixed value operation terminates
image3-13Program running stop screen
4. Run related operation settings
[image4-1]Operation related setting screen
① From the program(pgm)And fixed value(FIX)Select a setting during operation.
② When setting a power outagepower onOperation.
? 停止:The operation of restoring the state to the stopped state when restoring power after a power outage
? Cold up:The operation of restarting the operation when restoring power after a power outage.
? Hot up:The operation of restoring the state to the state before the power outage when restoring power after a power outage.
③ When locked on, all parameters(PARAMETER)The settings are all unusable.
④ When changing the set value, it can automatically increase or decrease according to the pre-set ratio.(Only applicable to fixed value operation)
⑤ The set time and[3.2.3fixed value(FIX)run 第 2 runtime screen]When the overall running time set in is the same, the operation will terminate.(Only applicable to fixed value operation).
⑥ Enter lock settings[scene4-2].
[image4-2]Enter the lock settings and enter the password
Enter password to enter lock settings: default is0
5. Program group configuration
?[3.1Main screen]Click the program group setting button in the middle to switch the screen to[image5-1Programming group setting screen].
? Parameters related to program group operation(PARAMETER)Set screen
[image5-1]Program setting screen
serial number |
Instruction content |
Content description |
① |
Program Editor |
Switch to the program editing screen |
② |
loop setting |
Switch to loop setting mode and partial loop screen |
③ |
Archives Management |
Switch to the setting mode to copy and delete the screen |
④ |
Cycle setting |
Switch to the screen for cycle setting |
⑤ |
Waiting for Settings |
Switch to the screen for setting waiting actions |
⑥ |
Test Name |
Switch to the screen for setting the test name |
5.1 Program editing settings
? Set the segment screen according to the program number.
? Please refer to the time signal setting[5.4Time signal operation].
? Please refer to the waiting action[5.5waiting action].
[image5-2]Mode editing screen
① Enter the number of the program group to be set.
② Set the temperature of the program segment to be run.
③ Set the humidity of the program segment to be run.
④ Set the time for the program segment to run.
⑤ You can choose whether to use the corresponding program segment's waiting action.
? reference[5.5waiting action]
⑥ Set the time signal for the program segment to be run
? Each program segment can be configured6A time signal, each time signal can be obtained from12Select settings from various categories.
? reference[5.4Time signal operation]
⑦ When inserting a program segment(Program segment01 ~ 99)Select from the key and click to activate(Program segment01 ~ 99)The selected key and(insert)Key, click(insert)Keys can be inserted into program segments.
⑧ When deleting a program segment(Program segment01 ~ 99)Select from the key and click to activate(Program segment01 ~ 99)The selected key and(delete)Key, click(delete)The key can delete a program segment.
⑨ Press4A fragment unit to the left/Move the screen backwards.
⑩ Switch to the second screen of program editing.
? click(Program ID)The key displays an input box for setting the mode number.
? Activate (segment)01) Key, can be activated(insert)、(delete)The key.
? click(temperature)The key displays an input box for setting the temperature.
? click(humidity)Key, can display the input box for setting humidity.
? Click (time))The key can display an input box for setting a time period.
? Click(TS)The key displays an input box for setting the time period.
5.2Program loop setting
? A screen for setting all or part of the loop function of a pre-set program.
[image5-3]Program and Partial Loop Setting Screen
① Set the program number that needs to be executed in a loop.
② Set the number of times the program has been set to run in a loop.
③ Set the program number that runs continuously when the program is terminated.
④ Set the program segment that starts the loop in the program that has been set.
⑤ Set the program segment that terminates the partial loop in the set program.
⑥ Set the number of iterations for a portion of the program that has been set to run repeatedly.
⑦ Set the experiment name for the set program.
? The experiment name can be changed at[5.6Experiment name setting]conduct.
? read-only(READ ONLY)Status cannot be changed.
5.3 Archives Management
?[5.1Program group configuration]The input can be entered into the programparameterThe value can be copied to other programs or deleted.
? Cannot delete the running program number.
? The deleted program cannot be restored.
[image5-4]Archives Management
① Set the original program number to be copied.
② Set the program start and end numbers for copying objects.
? The end mode is“0”Only copy the starting program.
③[5.1Program group mode setting]Display the total number of programs set in.
? read-only(READ ONLY)Status cannot be changed.
④[5.1Program group mode setting]Display the total number of program segments set in.
? read-only(READ ONLY)Status cannot be changed.
⑤ Set the start and end numbers of the program to be deleted.
? The final program is“0”Only delete the starting program.
⑥ Copy the program set in ① to the program set in ②.
⑦ Initialize the program settings set in ⑤.
⑧ Initialize all program settings.
5.4 Cycle setting
? Cycle setting is divided intoON/OFFOperation and time cycle setting operation, where the set cycle is used for[5.1Program group mode setting]When setting the time signal period in the program segment settings.
5.5 Standby settings
? During the operation of the program group, a screen is set to display the temperature and humidity waiting range and time for waiting actions.
? The waiting action set here is applicable to[5.1Program group program settings].
※Waiting action definition
① Waiting for the action to enter the condition(“OR”Conditions)
? When neither temperature nor humidity enters the waiting action setting range within the set program period time
② Waiting for the action to release the condition(“AND”Conditions)
? When both temperature and humidity enter the waiting action setting range
③ No waiting time set(initial value)If so, the default waiting time is infinite.
[image5-10]Standby settings
① Set whether to use wait action.
② Set the temperature range applicable for waiting actions.
③ Set the humidity range suitable for waiting actions.
④ Set the temperature or humidity setting value(TEMP PV or HUMI PV)The applicable waiting time when unable to enter the waiting action range.
? The waiting time is set to 00.00At this time, it will wait indefinitely until it enters the waiting action range.
⑤ Set whether to use linear mode.
5.6 Experiment name setting
? Set the name of each program experiment.
? Please refer to[image3-9Program execution(PROGRAM)第1 runtime screen]
[image5-11]Experiment Name Setting Screen
① Enter the experiment name for each program.
② Switch to the previous or next experiment name screen.
? click(name)The key displays an input box for setting the experiment name.
[image5-12]Experiment name input screen
* Zui Multi input20One character(10Chinese characters)
6. Historical Curve and Storage Devices
[image6-1]Historical curve display screen
[image6-2]Curve Setting Screen
[image6-3] USBStorage device screen
7 Screen display settings
7.1 Screen display settings
[image7-1]Screen display settings
① Language selection.
② Is the setting button displayed on the monitoring screen.
③ Calibrate the touch screen.
④ Set whether to use a prompt sound.
? Even if set to not be used, it occursDIThe prompt sound will not turn off when there is a malfunction.
⑤ Backlight energy-saving time can be set.
? The energy-saving working time setting refers to how long the backlight should be turned off when there is no need to operate buttons.
⑥ Set user password.
7.2 DIView fault occurrence records
? Display fault occurrenceDIScreen displaying the type, date, and time.
? The most numerous fault records can be displayed 30One.
? If the number of faults exceeds30Starting from the fault number before 'zui', delete it, and any subsequent faults will be connected after 'zui'.
[image7-2] DIFault occurrence record screen
① displayDIFault occurrence record.
? display[Installation Manual]of[11.2Fault Name]The name set in.
? Read only status, cannot be changed.
② Delete allDIFault occurrence record.
③ You can view the previous or next fault record.
8 Time Setting
? Screen for setting the current time and scheduled running time.
[image8-1]Time setting screen
① Set the current year, month, day, and time.
?The current time cannot be changed during operation.
② Set the scheduled operating year, month, day, and time.
③ click(appointment)The key can run at the set appointment time.
? click(appointment)Key, such as[image8-2run Appointment setting screen]As shown, the scheduled time will be displayed on the operation screen.
[image8-2]Operation reservation setting screen
9 通信故障
? When there is an abnormal connection to the control board, a prompt saying 'Control module not connected' will appear.
[image10-1]Communication malfunction screen
※Reason for communication interruption:
① Poor communication connection
② Poor connection status of communication cables