New version of xenon lamp weather resistance test chamber operation manual
Date: 2018-09-19Read: 0

Xenon lamp weather resistance test chamber

Instruction Manual

With the continuous development of modern industrial technology and the increasingly broad application fields of electronic and electrical products and their materials, the environmental conditions they experience are becoming more and more complex and diverse. Only by selecting materials and environmental protection measures reasonably can products avoid damage during storage and transportation, and be safe and reliable in use. Therefore, conducting artificial simulated environmental tests on products and materials is an essential part of ensuring their high quality.

Artificial natural environment simulation test is a scientific summary of actual environmental testing, which has the advantages of typicality, standardization, convenient use, and easy comparison. The diversity of environmental conditions and the importance of environmental testing have put forward higher and stricter requirements for environmental testing equipment.

Shangce specializes in the research and production of environmental testing equipment, and has accumulated rich experience in the field of environmental testing equipment. The company takes technology and quality as its tenet, and the "*" concept as its management foundation. It has established a sound quality assurance system and testing platform, and its products are widely used in aviation, military, scientific research, electronics, automobiles, motorcycles and other fields.

In order for you to quickly understand and operate the equipment correctly, we have carefully prepared this operation and maintenance manual. When you start the equipment, you must read it thoroughly and place it near the equipment. You must follow the items and operation methods listed in this manual to ensure the smooth completion of the experiment.

1、 Product Overview

Xenon lamp weather resistance test chamberIt is a test equipment that uses xenon lamps as light sources to simulate and enhance weather resistance and accelerate photo aging, in order to quickly obtain near atmospheric aging test results and evaluate the weather resistance of materials. Weather resistance test is an important means of screening and optimizing product composition in the scientific research and production process, and it is also an important content of product quality inspection. Materials such as coatings, plastics, aluminum-plastic panels, and automotive safety glass are required to undergo weather resistance tests according to product standards.

The main factors causing material aging are sunlight and humidity. The weather resistance test chamber can simulate the hazards caused by sunlight, rainwater, and dew. The weather resistance test chamber uses xenon lamps to simulate the effect of sunlight exposure, and uses condensed moisture to simulate rainwater and dew. The tested material is placed in a cyclic program of alternating light and moisture at a certain temperature for testing. It takes several days or weeks to reproduce the hazards that occur outdoors for months or even years. Artificial accelerated aging test data can help select new materials, modify existing materials, and evaluate how changes in formulations affect product durability.

IIMain technical parameters of the main lamp weather resistance test box:

1. Temperature range: 10 ℃~80 ℃

2Humidity range: Light cycle 50%~98% R.H, dark cycle 30%~98%

3Blackboard temperature: 63 ℃, 100 ℃ (deviation ± 3 ℃)

4Temperature fluctuation: ≤± 0.5 ℃

5Temperature uniformity: ≤± 2.0 ℃

6Humidity fluctuation:+2% to -3% R.H

7Glass window filter:

8Xenon lamp light source: imported air-cooled xenon arc light source

9Rainfall duration: 1 to 9999 minutes,Continuous rainfall adjustable

11Rainfall cycle: 1-240 minutes,Interval (interval) rainfall adjustable

12Spray nozzle aperture: Ø 0.8mm(Return water with ultra-fine filter to prevent nozzle blockage)

13Rainwater pressure: 0.12-0.15kpa

14Heating power: 3.5KW

15Humidification power: 2KW,

16The light cycle can be continuously adjusted for 1 to 999 hours

17Spectral wavelength: 290nm to 800nm. The irradiance range is adjustable from 100W to 800W/㎡.

18. Refrigerant: Environmentally friendly refrigerant R404A

19. Power supply: AC220V ± 10%, 50HZ

3、 Structure and Function

thisXenon lamp weather resistance test chamberIt uses xenon arc lamps (or carbon arc lamps) that simulate natural sunlight as the light source, and is equipped with suitable spectral requirements for testing, blackboard thermometers, and temperature, humidity, and water spray devices to simulate testing under specific natural environmental conditions.

1Control method: Time relay control (detailed operation can be found in the instrument manual)

2Water spray cooling device:

The water spray cooling system of the product is controlled by a temperature controller. When the temperature of the test chamber exceeds the set temperature, the water spray cooling system automatically sprays water for cooling regulation.

3 .Raining system device:

The rain protection system of the product consists of components such as water pump, sprinkler pipe, and time relay control. The spraying cycle is adjustable, and it is recommended to set the spraying cycle60min/12min.

4. Sample rack:

Rotational speed of the sample holder360Adjustable degree, rotating around the light source,At least the sample rack can be suspended10A test sample.(Please refer to the attached page for the diagram)

5. timing device:

To record the working time of each experiment,The product is equipped with a timer on the control panel,Can control the device time,The device will automatically shut down upon timed termination.

6Protection device:

Current overload protection.

Water shortage protection.

  • High speed circuit protector (protecting heating)
  • Electric motor (blower/freezer) overload thermal relay (protects blower/freezer from overload)
  • High pressure switch for freezer (protects compressor, extends service life)

Circuit breaker for protecting electric motors (refrigerators) (protecting compressors, extending service life)

four 、 Installation environment

1. The product should be installed in a relatively clean environment,There is less dust in the air,In an environment without corrosive and harmful gases.

2. The product has no special requirements for the temperature and humidity of the environment,But it should also be avoided to install at temperatures that are too high or too low,And in very humid or particularly dry environments. Ambient temperature10~35℃

3. Xenon arc lamps and filters are fragile items, so they should be installed firmly when leaving the factory,Special care should be taken during installation to avoid unnecessary losses.

5、 Maintenance and Precautions!

  1. Operating equipment must avoid moving parts such as equipment rotation to prevent personal injury.
  2. Xenon lamps that are ignited must not be observed directly or by other methods without isolation.
  3. During use, it is advisable to avoid frequent ignition of xenon lamps as much as possible,To delay the service life of xenon lamps,After the xenon lamp is turned off, the reignition time should not be less than10minute.
  4. The water used during the experiment must be clean distilled water,To prevent other impurities from contaminating the components and samples of the instrument.
  5. Regularly check whether the waterway system is unobstructed,If there is a blockage in the nozzle, it can be cleared with a metal wire and cleaned. Listen carefully.
  6. The luminous efficiency of xenon lamps will decrease after a certain period of use,The lamp tube should be replaced with a new one.
  7. After the experiment is completed, the power circuit breaker should be pulled down,Turn off the xenon lamp cooling water.
  8. If electrical components malfunction and need to be repaired or replaced, please replace them with the same model of components.
  9. The equipment should be operated and maintained by dedicated personnel.
  10. After long-term testing,Clean the water storage tank.
  11. When starting the sample rack speed controller,Be sure to turn on the power switch before turning on the speed control knob,The stop time should be set to zero by turning the speed control knob first,Turn off the power switch again.