Sievers analyzer will carry the full rangeTotal Organic Carbon (TOC) AnalyzerandEclipse Lunar Eclipse Bacterial endotoxin TesterMeet with you. Welcome to our booth!

Sievers analyzer booth number
E2 Hall 2357

Exhibition Time
Wednesday, September 6th, 9:00-16:30
Thursday, September 7th, 9:00-16:30
Friday, September 8th, 9:00-14:00
location
China International Exhibition Center (Shunyi Hall)
No. 88 Yuxiang Road, Shunyi District, Beijing
traffic
5 minutes' walk from Guozhan Station on Metro Line 15

Immediately proceed with pre registration for the visit
Long press the image to recognize the QR code in the picture

Instrument Introduction

Sievers®analyzeryesmajorTotal organic carbontoc analyzerAs a manufacturer, our design and manufacturing aim to help users perform analysis, measurement, and control more simply, quickly, and accurately. Sievers' solutions include TOC analyzers and sensors, standard products (certified by ISO 17034 and ISO/IEC 17025), and customized support services that can be quickly implemented, reduce costs, enhance users' ability to tackle challenges, and help sustain your system performance. The Sievers Total Organic Carbon (TOC) analyzer adopts professional membrane conductivity detection technology, which is accurate. Our instruments include laboratory, online, portable and other types, and are widely used in industries such as pharmaceuticals/biology, cosmetics and personal care, health products, electronics/semiconductors, municipal drinking water, sewage, industrial water, electricity, university research institutions, food and beverage, etc.
innovativeSievers®Eclipse®Lunar eclipse bacterial endotoxin detectorBy utilizing precise microfluidic processing and embedding endotoxin for automated dynamic colorimetric assay, the detection volume of 21 samples on each plate is achieved without the need for complex robot technology or the time and technical requirements required for traditional assays.
Up to 85% reduction in laboratory preparation time
Can complete laboratory preparation in as little as 9 minutes
Up to 89% reduction in pipetting steps can be achieved
Reduce the usage of horseshoe crab reagent by 90%
Simultaneously meet all relevant requirements of the United States Pharmacopeia USP<85>, European Pharmacopoeia EP 2.6.14, Chinese Pharmacopoeia ChP Part IV<1143>, and Japanese Pharmacopoeia JP 4.01
Compliant with 21 CFR PART 11 and data reliability criteria
Sievers®Ultra pure water BORON boron analyzerCan be used for deionized ultrapure water applications to achieve continuous automatic online monitoring of ultra-low boron content. This analyzer can detect 10 samples per hour and has a detection limit (LOD) of 15 ppt boron. The Sievers boron analyzer is designed to meet the needs of equipment managers, deionized water engineers, and wafer manufacturing engineers. It can predict mixed bed failures, optimize EDI performance, and control the boron level of polishing circulating water. This boron analyzer can detect an increase in boron content before the release of silica, which helps prevent silica from leaking into ultra pure water. Sievers boron analyzer can significantly reduce operating costs and maintain the quality of ultrapure water systems.