Selection of IPX12 Vertical Drip Test Device
Selection of IPX12 Vertical Drip Test Device
Test standard:
comply withIEC60529:2001《Degrees of protection provided by enclosures(IP Code)》TheGB4208-2008The Protection Level of the Shell(IPcode)How to translate14.2.1、 3 14.2.2Terms and figuresand GB7000.1Lighting fixturesPart: General Requirements and Tests
9.2.3
Clause requirements.Purpose: that
The main function of the device is for electronic purposes
- Electrical products, lamps, cabinets, electrical components, automobiles, motorcycles, and their parts are tested for their physical and other related properties under simulated rainy weather conditions. After testing, the performance of the product is evaluated through calibration to determine whether it meets the requirements, in order to facilitate the design, improvement, calibration, and factory inspection of the product.
- Product Features:
-
Suitable for conducting IPX1 and IPX2 tests on products.Wall mounted structure, drip tray runs smoothly.The equipment rack and sample turntable are all made of aluminum alloy and
-
SUS304#Stainless steel plate ensures long-term use without rusting.Water tank lifting drive:lead screw(SUS303stainless steel
- T32X6)
- The nut device drives the lifting and lowering, and has safety functions such as anti falling. When there is an object pressing against the water tank below, the nut will automatically detach from the water tank, which has the function of preventing damage to the water tank and various objects.
-
Drip board: Designed with vacuum and made of high rust resistant stainless steel material, it is durable and long-lasting.Drip flow rate: The flow meter comes with a regulating valve that can be manually adjusted.The rainfall device can automatically lift and lower, and the nozzle is located at the high point of the tested object
-
200mmAutomatically stop at any time (detected by photoelectric switch).Test needle: diameter
- 0.4mm
-
, * meets the testing standards; Detachable, easy to replace.The nozzle contact position is designed with a brass cone shape, allowing for needle replacement without the need for tools; A stainless steel mesh protective cover is installed under the needle, effectively preventing the test operator from accidentally touching the test needle and getting injured.
- Filtering measures: Standard equipment configuration
-
High precision filters can effectively filter impurities in tap water; The filter element can be replaced regularly.Equipped with compressed air air drying function: After the test is completed, excess water in the drip box can be completely removed to avoid long-term accumulation of water, scaling, and blockage of pinholes.The turntable motor adopts a stepper motor, and the turntable speed can be directly set on the touch screen; Can guaranteeIPX1Standard required turntable speed(1r/min)And it can be automatically completed4IPX2Testing requirementsDripping rain at each location
-
2.5min7The experimental requirements.Control system: Taiwan, China VelonInch touch screen+Panasonic
PLC |
1 |
. |
Technical parameter table: |
Dripping area |
2 |
800*800mm |
1000*1000mm |
Equipment external dimensions |
3 |
L1000×D1000×H2500 mm |
L1200*D1200*H2500mm500rotary table diameter |
¢600mm |
4 |
¢ |
mm |
5 |
Drip aperture |
¢0.4mm。 |
6 |
Inter hole distance |
20*20 mmprecipitation |
7 |
1-5mm/Min( |
±0.5mm/min) |
8 |
Traffic adjustment method |
manual adjustmentDrip box lifting height |
9 |
1000*1800 |
adjustable |
10 |
Rotating platform load-bearing capacity |
50KG |
11 |
Turntable speed |
01 r/minTilt angle of turntable |
12 |
° or |
15° |
13 |
Turntable lifting range |
fixed type |
14 |
Test time |
0-999 min |
15 |
protective device |
Leakage, water shortage, short circuit |
16 |
Power (V) |
3 |
17 |
380V |
Power (KW)meet the standard |