E-mail
122092220@qq.com
-
Phone
15800931558
-
Address
Room 202, Building 3, No. 38 Jianyun Road, Zhoupu Town, Pudong New Area, Shanghai
Shanghai Sanben Environmental Protection Technology Co., Ltd
122092220@qq.com
15800931558
Room 202, Building 3, No. 38 Jianyun Road, Zhoupu Town, Pudong New Area, Shanghai
Typical Applications
Widely used for online monitoring of dissolved oxygen in thermal power, chemical industry, metallurgy, water treatment, pharmaceuticals, biochemistry, electronics, electroplating, printing and dyeing, chemistry, food, and tap water.
Instrument Features
● Multiple configurations. The ordinary configuration uses an 8-bit microcontroller and the configuration uses products such as a 32-bit machine, ARM system, and CAN bus replacement technology, which belong to highly intelligent and reliable instruments. Chinese character menu style operation
The oxygen electrode has high sensitivity, short response time, high temperature resistance, collision resistance, corrosion resistance, and no deformation. It is easy to maintain and replace molds
LED dot matrix LCD display, displaying data, status, and operation prompts in Chinese, with adjustable background light
● Automatic temperature compensation
● Store over 500 sets of data
Automatically record historical events such as instrument status, faults, and occurrence time, commonly known as notepad function
● Using USB 2.0 communication port for data transmission
● Built in high-energy lithium battery, charged through computer USB port or charger, automatically protected against overcharging
Technical instructions
★ Measurement range: (0-100.0) µ g/L; (0~200.0)µg/L; (0-20.00) mg/L (automatic switching)
Temperature: (0-60) ℃ Resolution: 0.1 ℃
★ Lowest detection limit: 0.1 µ g/L
★ Overall indication error: ± 1% FS, temperature: ± 0.5 ℃; ± 2% FS (temperature out of tolerance condition difference)
★ Repeatability of whole machine indication: ± 0.5% FS; ± 1% FS (temperature deviation condition difference)
★ Stability of whole machine indication: ± 0.5% FS/4h ± 1% FS (poor temperature deviation conditions)
★ Automatic temperature compensation range: (0-60) ℃, with 25 ℃ as the reference
★ Response time:<20-60 seconds (90% of final value, 25 ℃) 37 ℃: 99% Final value<60-120 seconds
★ Communication interface: RS232
★ Clock accuracy: ± 1min/m
★ Water sample flow rate: (100-400) mL/min
★ Data storage quantity: 40d (1 point/5min)
★ Data power failure storage time: 10Y
★ Continuous working time of the whole machine: 36h (fully charged)
★ Power supply: Built in power supply 2 × 3.6V lithium batteries, charging power supply 220V ± 10% 50 ± 1Hz
★ Header dimensions: 210 × 110 × 46 (mm) length × width × height
★ Weight: 2.4kg (including suitcase)
★ Working conditions: Extreme ambient temperature: (0-60) ℃ Normal temperature: (10-40) ℃
Relative humidity:<85%