DSVDilute solution viscosity meter/Y501 relative viscosity meterIt is the earliest to provide comprehensive services to customersViscosity testing system. Whether you need a manual detection system for limited sample size testing or a fully automated injection detection system for high-throughput, safe, and highly reproducible testing, DSV can meet your needs.
Unlike the glass capillary viscometer, which detects the time it takes for a solution to pass through the capillary,the United StatesHMJcompanyDSVThe dilute solution viscometer uses pressure changes to detect relative viscosity. Two capillaries are connected in series, and the injection valve is located on both capillaries 1 and 2 middle The differential pressure sensor detects the pressure drop at both ends of each capillary tube. When the sample is injected into the second capillary, the differential pressure sensor detects the capillary2Changes in pressure on top (Figure)3). Relative viscosity is equal to the ratio of two capillary pressure drops multiplied by the instrument constantK.
Due to the high sensitivity of the relative viscometer, it is only necessary to detect a sufficiently diluted solution to directly obtain the desired viscosity without extrapolating from the United StatesHMJcompanyDSVThe dilute solution viscosity meter provides an accurate and high-precision method for fully automatic detection of solution viscosity.



Application advantages
❖ Save more than traditional methods50%The above solvents
❖ The detection speed is much faster than traditional glass viscometers
❖ Higher accuracy and precision
❖ *Not in contact with solvents, providing a truly safe operating environment for operators
❖ Flexible configuration according to customer needs
DSVThe relative viscometer can output the following results:

Application field
➠Polyethylene terephthalate(PET)
➠polyvinyl chloride(PVC)
➠polyolefin(Polyethlene)
➠polybutadiene(PBD)
➠Polycarbonate(PC)
➠Various types of polysaccharides
➠ synthetic rubber(EPDM)
➠ polylactic acid (PLA)
➠ hyaluronic acid(HA)
➠ cellulose
➠ nylon
Technical Specifications
Y-501host |
|
Measuring principle |
Dual capillary dual pressure sensor |
test scope |
0 – 20 cp(mPa. s)Or1 - 10Relative viscosity |
sensitivity |
1.0 x 10-4 Increasing specific viscosity |
Accuracy of relative viscosity testing |
+/- 0.1%relative standard deviation |
Typical flow velocity |
1 –3 mL/min. |
Typical analysis time |
2 –4 min. |
Typical sample volume |
20–25 mLRepeat the injection twice |
Capillary size |
0.02 in. ID x 12 in. |
shear rate(typical) |
1000 1/sec |
temperature range |
15–150°C |
output signal |
0 –10 V |
autosampler |
|
software control |
passETATMDilute solution viscosity control software package |
Number of sample bottles |
30 |
Software system and result output |
|
data collection |
Test time:infinite |
Number of data collection points:infinite |
|
output result |
Relative viscosity(Relative Viscosity) Increasing specific viscosity(Specific Viscosity) Logarithmic viscosity of specific concentration(Inherent Viscosity) Specific viscosity(Reduced Viscosity) Intrinsic viscosity(Intrinsic Viscosity:Soloman-GottesmanTheBillmeyerThe HugginsTheKramerTheBaker-Philopoff) Absolute viscosity(Absolute Viscosity) Dynamic viscosity(Kinematic Viscosity) molecular weight |