The volume of construction projects has been expanding year by year, and dust and noise have become one of the main sources of movement for urban atmosphere and sound environment. Deploying the "Smart Construction Site Environmental Monitoring System" can achieve pollution measurability, over limit alarm, and traceable results at the source. Its core advantages are reflected in the following six points:
Real time visualization
Continuous collection of PM2.5, PM10, TSP, noise, wind speed and direction, temperature and humidity. The on-site LED and monitoring platform are synchronized and refreshed, and the data is open and transparent.
Over limit warning
Built in national standard threshold, once particulate matter or noise exceeds the standard, sound and light alarms will be triggered, linked with dust reduction facilities such as sprinkler and high enclosure, and intervention will be completed within 30 seconds.
Extreme DUAN Weather Prevention
Access weather radar data, and push gale, rainstorm, sand dust, and high temperature warnings 48 hours in advance, so that the project can start emergency response in time, and reduce slowdown and equipment damage.
Data driven management
Automatically generate a "weather pollution construction" timeline, export reports in accordance with the supervision log format with one click, provide original evidence for construction period claims and environmental appeals, and shorten the claim cycle by an average of two weeks.
Government cloud integration
The system data is directly transmitted to the backend of the housing and ecological environment departments through APIs, eliminating the need for paper ledgers and reducing manual submission costs.
Social Responsibility and Brand Image
Publicly display real-time monitoring results, actively accept social supervision, enhance corporate ESG disclosure materials, and assist in green construction demonstration sites, Luban Awards, and green construction three-star evaluations.
Technical Points
Monitoring indicators: PM2.5, PM10, TSP, noise, wind speed and direction, temperature and humidity, atmospheric pressure, expandable CO, NO ₂, SO ₂, CO ₂, video.
Data frequency: default 1-minute sampling, 3-minute upload, supports second level triggering.
Communication method: 4G/5G/NB IoT/Ethernet, breakpoint resume, TLS encryption.
Installation requirements: The sampling port should be 3-5 meters high, at least 1 meter away from the edge of the foundation pit, powered by 220 V, and solar energy can be selected.
Standard basis: Meet the relevant requirements of HJ 653, HJ 212-2017, GB 3096-2008, GB 3095-2012, etc.