Shanghai Botuo Instrument Co., Ltd., if you have project requirements, please feel free to contact us at any timeSales Engineer:Wang Yuzhang, Consultation
Monitoring factors for sewage wells:
Flow rate, liquid level cod、 Ammonia nitrogen pH |

feature1. Low power consumption;
2. Powered by mains electricity or lithium batteries;
3. Monitoring factors: pH, suspended solids COD、 Parameters such as ammonia nitrogen, conductivity, flow rate, liquid level, etc,
4. The data output standard is RS485 protocol, which can be remotely sent through wireless modules such as RTU
5. The sensor has calibration and self-cleaning functions, no reagents, and low maintenance.
Shanghai Botuo Instrument Co., Ltd., if you have project requirements, please feel free to contact us at any timeSales Engineer:Wang Yuzhang, Consultation
Overall performance indicators
parameter |
Technical Specifications |
data storage |
Storage time 365 days |
data transmission |
RS485 output, sent by wireless module |
weight |
About 5kg |
ambient temperature |
0~55℃ |
relative humidity |
5%~85% (no condensation) |
power supply |
24V, Primary lithium battery 170AH/220V |
sensor interface |
2-channel sensor interface, IP68 waterproof connector |
Sensor cleaning |
1 cleaning interface, supporting turbidity and COD brush hanging, IP68 protection level |
sampling interval |
1-1440 minutes, adjustable |
battery life |
Half a year (15 minute measurement interval) |
Product advantages
Integrating collection, storage, transmission, and power supply;
2. Adopting digital sensors, self-cleaning, reagent free, maintenance free;
3. Large capacity lithium battery, capable of continuous operation for more than six months with a collection time of 15 minutes;
4. IP68 waterproof rating, supporting sensor recognition, plug and play, and easy maintenance;
5. The accompanying APP observes data and completes sensor calibration on the PC end;
6. The sensor is equipped with effective protection such as a protective cover;
7. Integrated IoT interface, supporting multiple transmission protocols;
Shanghai Botuo Instrument Co., Ltd., if you have project requirements, please feel free to contact us at any timeSales Engineer:Wang Yuzhang, Consultation
Water type |
sewage well |
Project Location |
Zhejiang |
sensor |
Underground data terminal+flow rate+pH+COD+ammonia nitrogen |
monitoring parameters |
Flow rate, liquid level cod、 Ammonia nitrogen pH |
Installation time |
2021.1 |
Analyze time period |
2021.1.15-2021.1.26 |
maintenance cycle |
30 days |
Report success rate |
99.6% |
data validity |
90% |