Performance characteristics of laboratory conductivity meter
Date: 2017-02-22Read: 36

Performance characteristics of laboratory conductivity meter
◆ Automatic calibration (Chinese version):
The instrument adopts button constant input calibration. When in use, you only need to input the constant value marked on the electrode into the instrument, and the BEC series can remember this value without losing it even if the power is turned off.
◆ Automatic Calibration (Version):
The instrument can be automatically calibrated at one point per range with standard conductivity solution. During calibration, the instrument automatically recognizes the calibration solution. If you use the wrong or significantly deviated conductivity solution for calibration, the instrument will automatically sound an alarm.
◆ Automatic range conversion:
When measuring conductivity, the instrument has an automatic range conversion function. After the electrode sensor is immersed in the solution, it will automatically scan the current measurement value and switch the range, and the screen will display the endpoint measurement value at the highest resolution.
◆ electrode constant can be set:
When measuring high or low conductivity solutions, you need to choose electrodes with different constants. The BEC series has three electrode constants to choose from, and you can set them according to the selected electrode. The instrument will automatically convert the endpoint measurement value.
◆ Temperature coefficient can be set:
Solutions containing different ions often have different temperature coefficients, and accurately setting the temperature coefficient is crucial for measurement. The BEC series can be set within the range of 0 to 3.9% per degree Celsius.
◆ Customized LCD display screen:
The instrument is equipped with a customized LCD display screen, which is simple and bright. It not only displays measurement values clearly, but also has operation mode icons, allowing you to have a quick understanding of the instrument's condition.
◆ Waterproof keyboard and electrode holder:
Assemble waterproof panels, acid and alkali resistant, so you don't have to worry about samples falling on the instrument and damaging it. The flexible electrode holder can be placed and stopped immediately, making it very convenient to use.
◆ Instrument configuration:
One DJS-1 platinum conductivity electrode, one 9V/350mA power adapter, and one BEC-120 temperature probe.
  Laboratory conductivity meterApplication field
The BEC series is applied in most fields related to water quality analysis, such as teaching, scientific research, and laboratories.
  Laboratory conductivity meterTechnical Specifications
Instrument Model BEC-110BEC-307BEC-120 Conductivity Measurement Range: 0~1.999, 19.99199.91999uS, 19.99200.0mS, Automatic 6-speed Conductivity Measurement Accuracy: ± 1.5% F.S ± 1% F.S ± 1% F.S Temperature Measurement Range: 0~100 ℃ Temperature Measurement Accuracy: ± 1 ℃ Temperature Compensation Range: 0~50 ℃, Manual: 0~50 ℃, Manual: 0~50 ℃, Manual or Automatic Temperature Compensation Coefficient: 0~3.9%/℃, Adjustable Optional Electrode Constant K=0.1,10 Instrument Calibration Point Chinese Version: Constant Input; Version: One point calibration power supply for each range, 9V/350mA power adapter, using 220V/50Hz power supply. Dimensions: 210 (L) × 205 (W) × 65 (H) mm. Instrument weight: 1.7kg