Product Overview:

The tunnel light intensity monitoring device can meet the requirements of the entire tunnel lighting control. The controller with preset control mode automatically switches the lighting switch according to the preset parameters based on the measured value of the light source, providing value for tunnel lighting. Its design complies with CIE's requirements for tunnel lighting measurement and can meet the "Design Specification for Ventilation and Lighting of Highway Tunnels". Moreover, its overall design can meet the requirements of harsh outdoor working environments.

Installation method:

The tunnel light intensity monitor is installed on the walls of the designated area inside the tunnel. In order to avoid damage caused by accidents or car debris, it needs to be installed at a height of about 4 meters and at an appropriate position greater than 10 meters from the tunnel entrance. Has high reliability and low maintenance Microprocessor technology, digital operation, easy installation and debugging.

Product Features:

According to the CIE specified human visual spectrum curve, a specially designed high-efficiency filter is used for calibration, which conforms to visual characteristics

Continuous linear proportional output, corresponding to accurate and sensitive measurement range of the equipment

Multiple signal output modes to adapt to different usage modes

Local data storage to avoid data loss in abnormal situations

The instrument casing has IP66 protection function, and the surface is coated with special paint, which has anti-corrosion ability

There is an output signal protection function to prevent abnormal situations from affecting user devices

Equipped with zero point compensation function

Technical Specifications:

Measurement range: 0-20000 lux

Measurement accuracy: 0.01lux

Measurement error: ± 1%

Measurement angle: Vertical ≥ 20 °, Horizontal ≥ 20 °

Analog output: 4~20mA

Transmission interface: RS485

Load impedance: 750Ω

Working temperature: -40 ℃ to+85 ℃

Working humidity: 0-100% RH

Protection level: IP66

Power supply mode: AC 90-305V