The GC3900Pro gas chromatograph is a professional version (performance version) with a 7-inch touch screen and stable voltage regulationFlow control flow path, optional(EPC Electronics
Flow and pressure control system, pressure and flow digital display function, abandoning mechanical display of pressure gauge), digital circuit,IP communication technology, bus technology, network transmission,
Digital quantity 485 transmission, realizing chromatographyInstrument online analysis, capable of remote control, etc., can be installed at mostThree types of detectors
Gas chromatograph is a separation and analysis tool for multi-component mixtures, which uses inert gas as the mobile phase and employs chromatographic column separation technology. When there are multiple fractions
When the analyte enters the chromatographic column, due to the different distribution coefficients of each component in the column, the flow velocities of each component in the column are different. After a certain period of
After the column length, the mixed components leave the chromatography column and enter the detector. After detection, they are converted into electrical signals and sent to the data processing workstation to complete the measurement of the tested components
Detection and analysis of substances.
|
Basic Application
| dimethyl ether | Dimethyl ether content in liquefied petroleum gas |
| indicator | parameter |
| Temperature of chromatographic column chamber
| Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃ |
| Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃ | |
| Temperature control area: 6-way temperature control | |
| Program heating order | 16th order |
| heating rate | 0.1-40 ℃/min, with increments of 0.1 ℃, initial and termination times Range: 0-6000min, with increments of 1min |
| Pressure protection method | The carrier gas has pressure protection function, and the gas pressure is lower than At 0.1MPa, the instrument automatically cuts off the power supply, effectively protecting the color Safe use of spectral columns |
| display mode | 7-inch touchscreen LCD display |
| Extreme temperature | Maximum protection value 450 ℃ |
| external event | 8通道外部事件 |
| Hydrogen flame ionization detector (FID)
| Ignition method: automatic ignition |
|
Mt≤5×10-12g/s(n-Hexadecane-Isooctane Solution) | |
| Noise:≤1×10-14A | |
| Drift:1×10-13A/30min | |
| Linear range: ≥ 106 | |
| power supply | 220V 50HZ 2000W |
| Instrument model | GC3900Pro (this instrument has automatic ignition function) | ||
| quantity | 1 unit | ||
| analyze samples | Dimethyl ether methanol | ||
| Sample components | Analysis of dimethyl ether methanol | ||
| configuration | Specification Model | quantity | |
| host GC3900Pro
| Room temperature ± 8 ℃ -450 ℃, in increments of 1 ℃ | ||
| Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃ | |||
| Temperature gradient: ± 1% | |||
| 16 stage program heating, heating rate 0.1-40 ℃/min, in increments of 0.1 ℃, Initial and termination time range: 0-6000min, with increments of 1min. | |||
| Extreme temperature: maximum protection value 450 ℃ | |||
| Injection system | Fill column injection system | 1 set | |
| detector
| Hydrogen flameDetector (FID)
| Mt≤5×10-12g/s(n-Hexadecane-Isooctane Solution) | 1 piece
|
| Noise:≤1×10-14A | |||
| Drift:1×10-13A/30min | |||
| workstation | Dedicated Workstation | 1 set | |
| chromatographic column | Capillary chromatography column |
Dimethyl ether methanol dedicated column | 1 piece |
| gas source | nitrogen cylinder | 99.999% high-purity nitrogen with pressure reducing valve (self equipped) | 1 bottle |
| Computer, printer | Computer, printer | Win7/ win10 | 1 set |