The GC3900Pro gas chromatograph is a professional version (performance version) with a 7-inch touch screen and stable voltage regulationFlow control flow path, optional(EPC Electronics
Flow and pressure control system, pressure and flow digital display function, abandoning mechanical display of pressure gauge), digital circuit,IP communication technology, bus technology, network transmission,
Digital quantity 485 transmission, realizing chromatographyInstrument online analysis, capable of remote control, etc., can be installed at mostThree types of detectors
Gas chromatograph is a separation and analysis tool for multi-component mixtures, which uses inert gas as the mobile phase and employs chromatographic column separation technology. When there are multiple fractions
When the analyte enters the chromatographic column, due to the different distribution coefficients of each component in the column, the flow velocities of each component in the column are different. After a certain period of
After the column length, the mixed components leave the chromatography column and enter the detector. After detection, they are converted into electrical signals and sent to the data processing workstation to complete the measurement of the tested components
Detection and analysis of substances.
|
Basic Application
| CO2 | Photocatalytic detection of CO2 reduction reaction |
| indicator | parameter |
| Temperature of chromatographic column chamber
| Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃ |
| Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃ | |
| Temperature control area: 6-way temperature control | |
| Program heating order | 16th order |
| heating rate | 0.1-40 ℃/min, with increments of 0.1 ℃, initial and termination times Range: 0-6000min, with increments of 1min |
| Pressure protection method | The carrier gas has pressure protection function, and the gas pressure is lower than At 0.1MPa, the instrument automatically cuts off the power supply, effectively protecting the color Safe use of spectral columns |
| display mode | 7-inch touchscreen LCD display |
| Extreme temperature | Maximum protection value 450 ℃ |
| external event | 8通道外部事件 |
| Hydrogen flame ionization detector (FID)
| Ignition method: automatic ignition |
|
Mt≤5×10-12g/s(n-Hexadecane-Isooctane Solution) | |
| Noise:≤1×10-14A | |
| Drift:1×10-13A/30min | |
| Linear range: ≥ 106 | |
| power supply | 220V 50HZ 2000W |
| Instrument model | GC3900Pro (this instrument has automatic ignition function) | ||
| quantity | 1 unit | ||
| analyze samples | Reactive gas | ||
| Sample components | H2TheO2TheN2TheCOTheCO2TheCH4TheC2H6TheC2H4TheC2H2Alcohols and acidsanalyze | ||
| configuration | Specification Model | quantity | |
| host GC3900Pro
| Room temperature ± 8 ℃ -450 ℃, in increments of 1 ℃ | ||
| Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃ | |||
| Temperature gradient: ± 1% | |||
| 16 stage program heating, heating rate 0.1-40 ℃/min, in increments of 0.1 ℃, Initial and termination time range: 0-6000min, with increments of 1min. | |||
| Extreme temperature: maximum protection value 450 ℃ | |||
| Injection system | Capillary column injection system | ||
| Injection system | Fill column injection system | 1 set | |
| detector
| thermal conductivityDetector (TCD)
| Sensitivity S ≥ 5000mV · ml/mg | 1 piece
|
| Noise ≤ 20 μ V | |||
| Drift ≤ 30 μ V/15 min | |||
| workstation | Dedicated Workstation | 1 set | |
| chromatographic column | Capillary chromatography column |
PQ column, GDX-502 column, 5A column | 3 pieces |
| gas source | nitrogen cylinder | 99.999% high-purity nitrogen with pressure reducing valve (self equipped) | 1 bottle |
| Computer, printer | Computer, printer | Win7/ win10 | 1 set |
1analyzeH2O2、N2TheCO、CO2TheCH4TheC2H6、C2H4TheC2H2

After the sample enters column 1 through valve 1, after the gas flows out of column 1, valve 1 switches to blow back alcohols, acids, etc. Column 2 separates C1 and C2. Among them, C1 is H2, O2
N2, CO, CH4 peak combination. After entering column 3, valve 2 switches. CO2 and C2 enter TCD through damping and then enter FID II through valve 3. Analyze C2H6
Content of C2H4 and C2H2. After C2 is completed, valve 2 is reset. Column 3 separates H2, O2, N2, CO, and CH4 into TCD. Detect H2, O2, N2, continue
Entering valve 3 (switching valve 3), it enters the converter, where CO is converted into CH4. Upon entering FID II, CO and CH4 are detected.
Note: Due toTCDLimited sensitivity,H2TheO2TheN2If the concentration is too low, it may not be detectable.
2、 Instrument and equipment
The gas chromatograph should be equipped with a thermal conductivity detector (TCD) and a hydrogen flame ionization detector (FID), gas six way valve, ten way valve, and solenoid valve