▏Product Features


◎This machine adopts a 5.7-inch LCD vertical display with a large Chinese screen, providing clear and intuitive images. 10 temperature control values (column box 1,2. Sample injector1,2,3,detection

Set and actual temperature values for devices 1, 2, 3, auxiliary 1, 2, etc., with reserved fault alarm location area and time displayDisplay area, event area, etc.

◎Can add status indicator lights and fault alarm lights to the instrument's temperature, time, events, range rise, stopwatch, and extreme temperature protection values on a universal basisDisplay, etc., systemTonggenggan people's culture,

Convenient.

◎Having core temperature control development technology, PID temperature control system, utilizing the characteristics of bus development technology, adopting control chips, and dual over temperature protection of temperature control software and hardware,Enable temperature controlThe system runs for a long time,

Reliable and durable


▏Test Principle


Gas chromatograph is a separation and analysis tool for multi-component mixtures, which uses inert gas as the mobile phase and employs chromatographic column separation technology. When multiple analyses are conductedMaterial entryDuring the chromatographic column, due to various factors

The distribution coefficients of components in the chromatographic column are different, and the flow velocities of each component in the chromatographic column are also different. After a certain column lengthAfterwards, the mixed componentsDon'tLeaving the chromatographic column and entering the detector, after detection

Convert into electrical signals and send them to the data processing workstation to complete the analysis of the measured substanceDetection and analysis.

▏Test application


Basic Application

heptafluoropropane

Polyfluoroalkane, molecular formula C3HF7

▏Technical Specifications

indicator

parameter

Temperature of chromatographic column chamber

Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃

Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃

Temperature control area: 7-way temperature control

Program heating order

16th order

heating rate

0.1-40 ℃/min, increments of 0.1 ℃, initial and termination time range: 0-6000min, increments of 1min

Pressure protection method

The carrier gas has pressure protection function. When the gas pressure is below 0.1mpa, the instrument automatically cuts off the power supply, effectively protecting the color

Safe use of spectral columns

display mode

320x240 Chinese vertical LCD display

Extreme temperature

Maximum protection value 450 ℃

external event

8通道外部事件

Hydrogen flame ionization detector (FID)

Ignition method: automatic ignition

Detection limit: Mt ≤ 5 × 10-12G/s (n-hexadecane-isooctane solution)

Noise: ≤ × 10-14A

Drift: ≤ 1 × 10-13A/30min

Linear range: ≥ 106

power supply

220V 50HZ 2000W

▏Product Configuration


Instrument model

GC3900PLus (this instrument has automatic ignition function)

quantity

1 unit

analyze samples

heptafluoropropane

Sample components

heptafluoropropaneanalyze

configuration

Specification Model

quantity

host

GC3900PLus

主图1.1.jpg

Room temperature ± 8 ℃ -450 ℃, in increments of 1 ℃

Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃

WenDegree gradient: ± 1%

16 stage program heating, heating rate 0.1-40 ℃/min, in increments of 0.1 ℃,

Initial and termination time range: 0-6000min, with increments of 1min.

Extreme temperature: maximum protection value 450 ℃

Injection system

Capillary injection system

1 set

detector

Hydrogen Flame Detector (FID)

Detection limit:Mt≤5×10-12g/s(Hexadecane)-Isooctane solution);

1 piece

Noise:≤5×10-14A

Drift:≤1×10-13A/30min

workstation

Dedicated Workstation

Anti control workstation

1 set

chromatographic column

heptafluoropropane

heptafluoropropaneSpecial column

1 piece

gas source

air generator

RNA-3000,3000ml/min

1 unit

hydrogen generator

RNH-300,300ml/min

1 unit

nitrogen cylinder

99.999% high-purity nitrogen with pressure reducing valve (self equipped)

1 bottle

Gas purifier

RNJ-2000, Trinity with valve switch

1 unit

Computer, printer

Computer, printer

Win7/ win10