The GC3900E touch screen gas chromatograph is a high-sensitivity chromatograph product developed and optimized on the bus development platform. It has a simple and clear Chinese display interface, making it very easy for beginners
Familiarize the product with clear menus, reasonable layout, real-time display of system parameters through Flash animation, and dynamic display of realistic graphics in a short period of time, so that the instrument is not monotonous
Gas chromatograph is a separation and analysis tool for multi-component mixtures, which uses inert gas as the mobile phase and employs chromatographic column separation technology. When multiple analyses are conductedMaterial entryDuring the chromatographic column, due to various factors
The distribution coefficients of components in the chromatographic column are different, and the flow velocities of each component in the chromatographic column are also different. After a certain column lengthAfterwards, the mixed componentsDon'tLeaving the chromatographic column and entering the detector, after detection
Convert into electrical signals and send them to the data processing workstation to complete the analysis of the measured substanceDetection and analysis.
Basic Application |
drinking water |
Determination of disinfection by-products in drinking water and/or source water by gas chromatography |
indicator |
parameter |
Temperature of chromatographic column chamber |
Temperature control range: room temperature ± 8 ℃ -450 ℃, with increments of 1 ℃ |
Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃ | |
Temperature control area: 10 temperature control channels | |
Program heating order |
16th order |
heating rate |
0.1-40 ℃/min, increments of 0.1 ℃, initial and termination time range: 0-6000min, increments of 1min |
Pressure protection method |
The carrier gas has pressure protection function. When the gas pressure is below 0.1mpa, the instrument automatically cuts off the power supply, effectively protecting the color Safe use of spectral columns |
display mode |
7-inch touch LCD display |
Extreme temperature |
Maximum protection value 450 ℃ |
external event |
8通道外部事件 |
Electron Capture Detector (ECD) |
Ignition method: automatic ignition |
Detection limit: ≤ 1 × 10-14g/s | |
Noise: ≤ 0.03mv | |
Baseline drift: ≤ 0.2mV/30min | |
power supply |
220V 50HZ 2000W |
Instrument model |
GC3900E (This instrument has automatic ignition function) |
||
quantity |
1 unit |
||
analyze samples |
Trichlorous acid-methane |
||
Sample components |
Trichlorous acid-methaneanalyze |
||
configuration |
Specification Model |
quantity |
|
|
host GC3900E
|
Room temperature ± 8 ℃ -450 ℃, in increments of 1 ℃ |
||
Temperature control accuracy: ± 0.1 ℃ - ± 0.2 ℃ | |||
WenDegree gradient: ± 1% | |||
|
16 stage program heating, heating rate 0.1-40 ℃/min, in increments of 0.1 ℃, Initial and termination time range: 0-6000min, with increments of 1min. | |||
Extreme temperature: maximum protection value 450 ℃ | |||
Injection system |
Capillary injection system |
1 set |
|
detector |
Electron Capture Detector (ECD) |
Detection limit: ≤ 1 × 10-14g/s |
1 piece |
|
Noise: ≤ 0.03mv | |||
|
Baseline drift: ≤ 0.2mV/30min | |||
workstation |
Chromatographic network anti control workstation |
HW-2000 |
1 set |
chromatographic column |
Capillary chromatography column |
SE-54 |
1 piece |
| gas source | nitrogen cylinder |
99.999% high-purity nitrogen with pressure reducing valve (self equipped) |
1 bottle |
Computer, printer |
Computer, printer |
Win7/ win10 |
1 set |