Product Overview:
The HD-DX water quality biotoxicity analyzer is a new generation of acute toxicity analyzer used in laboratories. It is a toxicity detection system based on biological fluorescence sensing technology, which qualitatively and quantitatively detects the changes in luminescence intensity of luminescent bacteria during metabolism. Compared with traditional biological detection methods such as fish, water fleas, and other aquatic organisms, the luminescent bacteria method is simple, fast, sensitive, adaptable, repeatable, accurate, low-cost, and widely used. It is a water toxicity rapid detection instrument designed for environmental pollution, emergency accidents, security checks, and routine testing purposes, and can be used for overall toxicity detection of heavy metals, toxic agents, nerve agents, pesticide formulations, and other substances in water on site.
Compliant with the national standard "GB/T15441-1995 Determination of Acute Toxicity of Water Quality - Luminescent Bacteria Method" and international standard (ISO 11348-3).
Application industry:
Biological pollution, toxic chemicals, toxic and hazardous waste, municipal drainage, rainwater testing, drilling fluid and mud testing, mining industry, wastewater, soil and water testing, industrial wastewater discharge testing, process water testing, seawater testing, medical/pharmaceutical product testing, food packaging testing, personal protective equipment and household chemical testing, sediment testing, rainwater runoff testing, solid sample testing, food processing water testing;
Detection principle:
The HD-DX biotoxicity detector performs dual functions: toxicity testing and determination of microbial contamination; Conduct toxicity testing using luminescent bacteria found in nature, which emit light during normal metabolic processes. If placed in a toxic environment, their cellular respiration process is affected, resulting in a decrease in luminescence. The HED-DX luminescence detector measures the luminescence of luminescent bacteria before and after exposure to toxic environments, and the degree of reduction in luminescence corresponds to the strength of toxicity. The detection results can be compared with the standard toxic substances HgCl2 or zinc sulfate heptahydrate to determine the corresponding toxicity level
Instrument features:
1. Compliant with national standards (GB/T15441 1995) and international standards (ISO 11348-3);
2. Biological early warning systems sensitive to over 3000 toxic compounds;
3. Obtain results within 15 minutes after sample preparation, which are fast, reliable, and reproducible;
4. The test results are highly correlated with other traditional toxicity analysis methods and can be applied to emergency water pollution detection to help users monitor in real-time whether the drainage complies with local regulations and discharge standards;
5Android intelligent operating system, more intelligent and user-friendly;
6. We have independently developed an automatic lifting detection device for biotoxicity darkrooms, which solves the problem of strong light affecting open lid testing in the industry; With the same amount of bacteria, our instrument can save 5 times the cost of consumables;
7. Portable PVC engineering box design, can be carried out for on-site testing;
8. 7-inch ultra large display touch screen, eliminating tedious button operations and making it more convenient;
9Using silicon photomultiplier tubes significantly improves detection sensitivity;
10. Equipped with RJ45, WIFI, 4G, and Bluetooth connection transmission functions, it can wirelessly transmit data to relevant monitoring and regulatory platforms, achieving real-time data and better meeting the scenario requirements of regulatory departments;
11. The instrument is equipped with a built-in 6000mAH lithium battery pack, which can support continuous operation for more than 8 hours in the event of external power failure or no power supply;
12. A curve can have 20 concentration points, and the curve points can be freely selected to participate in the calculation of the entire curve without manual recording, ensuring more accurate curve values; (The concentration points on the curve can be customized and increased)
13. The instrument has a built-in ROM of ≥ 4GB and can store over 80000 data results;
14. Equipped with USB communication interface, convenient for data reading and export, exporting results as Excel spreadsheets;
15. Built in Pinyin input method, capable of editing both Chinese and English information;
16. High speed thermal printer, capable of automatically printing inspection reports upon completion of testing, with accompanying QR codes for easy scanning and traceability;
17. The instrument has a built-in operation demonstration video. Click on the main interface operation video to automatically play it, which is convenient, fast, and easier to get started with;
18. The detection history query function allows for the selection of start and end times to retrieve previous detection data, which is accurate and convenient;
19. Optional GPS positioning function, real-time display of detection location information;
Parameter indicators:
Detection method: luminescent bacteria method
Detector: Silicon photomultiplier tube
Spectral range: 300-1100nm
strain:Bright luminescent bacteriaVibrio fischeri, Vibrio qinghaiensis, Vibrio oxysporum, etc;
Method standards: GB/T15441-1995&ISO11348
Repeatability: The sample is measured three times with a relative deviation of less than 1%
Sensitivity: Equivalent to or better than the acute biotoxicity test method for fish cultured for 96 hours;
Test time: Obtain results within 15 minutes after sample preparation
Display results: detection value (mg/L)/toxicity prompt (low toxicity, toxic, severe toxicity, high toxicity, highly toxic) displayed according to standard requirements
Print settings: sample name, testing personnel, testing location, reference poison
Operating environment: Storage temperature -10~50 ℃, working temperature+5~45 ℃
Relative humidity: 30-95% (25 ° C)
Data storage: over 80000 records
Communication: RJ45, WIFI, 4G, USB, Bluetooth
Battery: 6000mAh lithium battery
Continuous working time: more than 8 hours
Power supply: 220V/12V AC/DC dual-use