Welcome Customer !

Membership

Help

Nanjing Ouxi Science and Trade Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>News

Nanjing Ouxi Science and Trade Co., Ltd

  • E-mail

    13913028277@163.com

  • Phone

    13913028277

  • Address

    Room 618, Tongchuang Building, No. 61 Sipailou, Xuanwu District, Nanjing City

Contact Now
Challenge wastewater treatment biodegradable experimental equipment in the United States
Date: 2017-01-09Read: 1

Aerobic/Anaerobic Breather(Microbial degradation respiratory apparatus)AER- 208
The respiratory equipment of the American Challenge brand has been continuously innovating in the market for 20 years, which is the * of customers.
Microbial degradation respiratory apparatusapplication
The AER-208 respirator can be used for wastewater treatment in cities, industries, research institutes, engineering institutes, universities, etc
Oxygen consumption rate measurement
Oxygen uptake rate control of activated sludge
Measure short-term BOD
Use dilution series for toxicity measurement
Measurement of acute toxicity
Degradation of wastewater samples
Measure nutrient deficiencies
Biodegradation of mixed wastewater
The inherent biodegradation of chemicals
Soil oxygen uptake rate and compost samples
Anaerobic biological activity testing
Anaerobic BMP and ATA testing
Microbial degradation respiratory apparatusInstrument Introduction
A user-friendly interface.
The screw cap bottle design allows for smaller sample sizes and shorter cleaning times.
Non electrolytic chemicals - only wastewater and oxygen.
The aerobic maximum resolution can be as low as 0.06 mg/O2, and the anaerobic reaction can reach 0.04 mL.
The aerobic maximum resolution can be as low as 10.8 mg/O2, and the anaerobic reaction can reach 7.2 mL.
Oxygen consumption rate: as low as 0.06 mg/hr, up to 600 mg/hr
Detection range of anaerobic gas production: 0.05 ml/hr -1500 ml/hr.
Personalized requirements for custom systems:
Standard configuration includes 8 reactors, expandable to 16 and 24 reactors.
Can provide both table and graphical data simultaneously and display them in real-time.
Flexibility of data collection: The time interval can be set between 1 minute and 720 minutes
The instrument usage training is very simple, read aloud

Display the pinyin of the corresponding Latin characters

Microbial degradation respiratory apparatusSpecification parameters:

Zui small resolution

The highest resolution

Calibration accuracy

sensitivity

measurement accuracy

aerobic

<0.06 mg

600 mg/hr

< 1% Cv

<0.06mg

<3%CV

anaerobic

<0.15mL

1500 mL/hr

< 2% Cv

<0.15mL

<3%CV