Main precautions for using a constant temperature and humidity incubator
Date: 2014-05-21Read: 0

Introduction to Constant Temperature and Humidity Test Chamber:

Biochemical incubators and mold incubators, as well as constant temperature cultivation devices for the cultivation and breeding experiments of molds and microorganisms, are ideal equipment for scientific research and production in fields such as biotechnology, medical research, agricultural and forestry science, aquaculture, and animal husbandry.

Function of constant temperature and humidity test chamber:

Controlled by a microprocessor, it has functions such as monitoring, temperature control, and protection. Indoor lighting: can observe the culture inside the box, stainless steel inner liner, and corrosion.

Precautions and maintenance of constant temperature and humidity test chamber

1. The working voltage of this box is AC 220V, 50Hz. Before use, it is necessary to pay attention to whether the voltage of the power supply used is consistent with the specified voltage, and the grounding electrode of the power socket should be effectively grounded according to the regulations.

2. When powered on, avoid touching the electrical parts on the left side of the box with your hands or wiping with a damp cloth or rinsing with water.

3. The power cord should not be wrapped around metal objects or placed in high temperature or humid places to prevent rubber aging and electrical leakage.

4. The test object should not be placed too tightly inside the box to ensure smooth air flow and uniform heating inside. The bottom plate of the inner chamber should be close to the electric heater, so it is not suitable to place the test object. In the laboratory, the air vent valve should be appropriately opened to facilitate temperature regulation inside the box.

5. When valuable bacterial strains and cultures are placed in the incubator, they should be observed frequently. In case of any abnormal situation, the power should be immediately cut off to avoid any external or unnecessary losses.

6. Do not open the temperature controller unless necessary to prevent damage.

7. After each use, the power must be cut off. Regularly keep the inside and outside of the box clean and the water inside the tank clean.

8. Be careful of burns when using at high temperatures.

9. The fuse tube is installed in the left space inside the box. When replacing it, the side door needs to be opened and the power must be cut off.