- Phone
-
Address
No. 318 Xiaowan Road, Fengxian District, Shanghai
Naidong Valve (Shanghai) Co., Ltd
No. 318 Xiaowan Road, Fengxian District, Shanghai
Product Introduction of Piston type Electro hydraulic Valve
1. Overview
Piston type electro-hydraulic valve is a device that controls fluid flow in hydraulic systems through electrical signals. It is widely used in industrial automation, engineering machinery, and other fields, and has the characteristics of fast response, high control accuracy, and strong reliability.
2. Working principle
Electrical signal control: By energizing an electromagnetic coil to generate a magnetic field, the piston is driven to move.
Piston movement: The movement of the piston changes the position of the valve core, thereby controlling the direction and flow rate of hydraulic oil.
Hydraulic control: By changing the position of the valve core, precise control of hydraulic actuators is achieved.
3. Main structure
Electromagnetic coil: After being powered on, it generates a magnetic field to drive the piston.
Piston: moves under the action of a magnetic field, driving the valve core.
Valve core: controls the flow of hydraulic oil.
Valve body: accommodates various components to ensure sealing and fluid passage.
4. Product Features
High response speed: Electromagnetic drive, rapid response.
Precise control: can accurately adjust flow and direction.
High reliability: simple structure and strong durability.
Multiple specifications: Suitable for different pressure and flow requirements.
Easy to maintain: Modular design, easy to maintain.
5. Application Areas
Industrial automation: used for hydraulic control of equipment such as machine tools and injection molding machines.
Construction machinery: hydraulic systems used in excavators, cranes, and other equipment.
Aerospace: Used for hydraulic control of aircraft.
Ship: Used for ship hydraulic systems.
6. Technical Specifications
Work pressure: usually10-31.5 MPa.
Flow range: Depending on the model, from a few liters to several hundred liters/minute
Power supply voltage: commonly referred to as24V DCor220V AC.
Operating Temperature-20°Cto80°C.
7. Selection Guide
Pressure level: Select based on system pressure.
Traffic demand: Select based on system traffic.
Power type: Select according to the control system power supply.
Environmental conditions: Consider environmental factors such as temperature and humidity.
8. Installation and Maintenance
Installation: Ensure that the valve body is firmly connected to the pipeline to avoid leakage.
Maintenance: Regularly check the electromagnetic coil, piston, and valve core, and replace worn parts in a timely manner.
9. Common problems and solutions
Valve core stuck: Clean or replace the valve core.
Electromagnetic coil malfunction: Check the power supply and coil, and replace them if necessary.
Leakage: Check the seals and replace them if necessary.
10. Summary
Piston type electro-hydraulic valves are widely used in various fields due to their high response speed and precise control capability. Proper selection, installation, and maintenance can ensure its long-term stable operation.