Characteristics of KEM's New Digital Density Meter DA-800 Series
1. High reliability: An internationally certified manufacturer of density standard fluids ensures instrument accuracy.
2. Equipped with camera function: improves the visibility of the measurement unit, displays real-time images, and can be stored.
3. Optional operating unit: Depending on your analysis style, you can choose a tablet or computer.
4. Reduce measurement time: Through evolutionary algorithms, 4-digit accuracy can be achieved in 10 seconds.
5. Multi channel measurement: The operating unit can control multiple measurement units, facilitating data management.
6. Complete functions: automatic bubble detection, full range viscosity correction, built-in air pressure correction.
7. Fully automatic cleaning: One click operation can automatically inject, measure, drain, clean and dry.
8. Small footprint: When connecting multiple sample automatic samplers externally, the main unit is placed above to save space.
Digital density meter DA-860 (six digits)
Measurement range: 0-3 g/cm3.
Temperature measurement: 0-100 ° C (32-212 ° F), with built-in Peltier temperature control.
Accuracy: Density: 3 × 10-6 g/cm3.
Repeatability: Density: 1 × 10-6 g/cm3.
Reproducibility: Density: 2 × 10-6 g/cm3.
Digital density meter DA-850 (five digit number)
Measurement range: 0-3 g/cm3.
Temperature measurement: 0-100 ° C (32-212 ° F), with built-in Peltier temperature control.
Accuracy: Density: 1 × 10-5 g/cm3.
Repeatability: Density: 5 × 10-6 g/cm3.
Reproducibility: Density: 5 × 10-6 g/cm3.
Digital density meter DA-840 (four digit number)
Measurement range: 0-3 g/cm3.
Temperature measurement: 0-100 ° C (32-212 ° F), with built-in Peltier temperature control.
Accuracy: Density: 5 × 10-5 g/cm3.
Repeatability: Density: 5 × 10-5 g/cm3.
Reproducibility: Density: 5 × 10-5 g/cm3.
Test method: U-shaped vibration tube method.
Sample requirements: manual injection of about 1mL, automatic pump injection of about 2mL.
Measurement time: The accuracy to four decimal places is approximately 10 seconds.
Display: Tablet or computer display.
Viscosity correction: Automatic viscosity correction function.
Measurement pool inspection function: automatically checks the dryness of the measurement pool, and the pump automatically stops when the measurement pool is dry.
Stability assessment: Adjust in five stages based on measurement accuracy and time.
Concentration conversion: Input density and concentration table or conversion formula to automatically convert concentration values.
Temperature compensation: Input density and temperature tables or conversion formulas to automatically perform temperature compensation.
Statistical calculation: automatically or manually calculate the mean, standard deviation, and relative standard deviation.
Interface: LAN, USB, RS-232C.
Power supply: AC100~240V, 50/60HZ, 40W.
Dimensions: 295 (W) × 330 (D) × 255 (H) mm.
Weight: 19kg.