Kyoto Electronics KEM Karl Fischer Reagent KEM AQUA
Date: 2023-11-21Read: 0


Kyoto Electronics KEM Karl Fischer Reagent KEMAQUA

KEM AQUA Karl Fischer reagent is a specialized reagent for Karl Fischer moisture meters produced by Kyoto Electronics Industry Co., Ltd.
The reagent product lineup is very rich and can be used for moisture determination of various samples.
There are also various standard substances suitable for moisture meters from various brands.
The cost-effectiveness is very high, which can reduce analysis costs.
This reagent is a specialized reagent provided by the manufacturer of Karl Fischer moisture analyzer.

Volumetric titration reagent
KEM AQUA titrant
Karl Fischer titrants are available in three types based on their moisture content.
KEM AQUA titrant can also be used to measure ketone and amine samples, so there is no need to change the titrant based on the sample.
■KEM AQUA Dehydration Solvent
Karl Fischer solvent is necessary for the dissolution and dispersion of samples.
There are five types of KEM AQUA dehydration solvents: general purpose, solvents for oils, fats, ketones, and sugar samples.
Select the most suitable dehydration solvent based on the properties of the sample. Used together with KEM AQUA titrant.

Coulombic coulometric reagent
■KEM AQUA anolyte AGE/catholyte CGE
Because it does not contain carbon tetrachloride and chloroform, it causes less environmental pollution and can be used with confidence.
When using the petroleum product determination and moisture gasification device, no other solvents need to be added and it can be used directly.
KEM AQUA anolyte AGE (100mL) can measure approximately 800mg of moisture, while KEM AQUA catholyte CGE (5mL) can measure approximately 150mg of moisture.
■KEM AQUA anolyte AO/catholyte CGE
It is the best combination for determining the moisture content of oil samples and petroleum products.
Has good solubility for petroleum products.
■KEM AQUA anolyte AKE/catholyte CGE
Because it does not contain chloroform and ethylene glycol methyl ether, it causes less environmental pollution and can be used with confidence.
Suitable for ketone, low content carboxylic acid, and some aldehyde samples.
KEM AQUA anolyte AKE (100mL) can measure approximately 300mg of moisture, while KEM AQUA catholyte CGE (5mL) can measure approximately 100mg of moisture.