E-mail
0937982501@163.com
-
Phone
13601731964
-
Address
Room 1201, Huixin International Building, 333 Yishan Road, Xuhui District, Shanghai
Kyoto Electronics China - Kemu Electronics (Shanghai) Trading Co., Ltd
0937982501@163.com
13601731964
Room 1201, Huixin International Building, 333 Yishan Road, Xuhui District, Shanghai
Handheld density meter DA-130N
The main features of the handheld density meter DA-130N are:
1. Digital densitometer with digital display LCD screen and diverse display content.
2. The measurement range is wide, the operation is very simple, the measurement accuracy is high, and the testing speed is fast.
3. The built-in pure water density meter is easy to calibrate, and can also perform air or standard substance calibration.
4. Ten sets of temperature compensation coefficients can be inputted to automatically perform density or relative density compensation.
5. The sample demand is small, and only one hand is needed to control the sampling volume and sampling speed.
6. The portable densitometer has a built-in suction pump that can extract liquids up to 2000mPa. s.
7. It can be quickly measured on-site or outdoors without worrying about the sample being sent to the laboratory.
8. Store 1100 sets of measurement results, and the data can be exported to an optional printer or computer.
9. Portable density meters can output results through infrared radiation and come standard with data collection software.
Handheld density meter DA-130N technical parameters:
Measurement principle: U-shaped tube oscillation mode.
Test substance: Suitable for various liquid samples.
Density measurement range: 0.0000-2.0000 g/cm3.
Density accuracy: 0.001 g/cm3.
Density resolution: 0.0001 g/cm3.
Temperature measurement range: 0-40 ° C.
Temperature resolution: 0.1 ° C.
Environmental temperature: 0-50 ° C.
Display content: density (specific gravity), temperature compensated density (specific gravity), relative density, temperature compensated relative density, sugar content (Brix%), alcohol concentration (wt%/vol%), sulfuric acid concentration (H2SO4), American Petroleum Institute degree (API °), Baume, Plato degree, alcohol strength (Proof), temperature (° C/° F), sample number, automatic stability judgment, data saving, output, clearing, date/time, battery consumption level ... wait.
Temperature compensation: 10 sets of temperature compensation coefficients can be input to automatically convert the density value of the required temperature. For example: ethanol, meta xylene, para xylene, glycerol, chloroform, carbon tetrachloride, toluene, benzene, methanol, acetone, bromobenzene, cyclohexane, isopropanol, nonane ... wait.
Automatic calibration: Perform automatic calibration on pure water density values at various temperatures, or use density standard solution for calibration.
Sampling method: manual pump syringe method (viscosity less than 2000mPa. s), or injection using a syringe.
Data storage: can remember up to 1100 sample measurement results.
External output: Built in infrared output, optional RS-232C cable for transmission to printer or computer.
Liquid receiving materials: injection tube (PTFE), measuring cell (borosilicate glass), concealed syringe (polypropylene).
Weight: Approximately 360 grams.
Power supply: DC 3V (alkaline battery 1.5V × 2).
Battery life: approximately 90 hours.