CO2 incubatorCO2 incubator is an instrument for cell, tissue, and bacterial culture, and is a key equipment necessary for immunology, oncology, genetics, and bioengineering. It is an improved version of ordinary culture, mainly capable of adding CO2 to meet the environment required for microbial cultivation.
CO2 incubatorFeatures: 1. The inner liner is made of mirror stainless steel or brushed plate argon arc welding, with four semi-circular corners that are easy to clean. 2. Microcomputer temperature controller with small temperature fluctuations. The box is equipped with ultraviolet sterilization lamps that can regularly disinfect the box with ultraviolet radiation, thereby more effectively preventing contamination during cell culture. 3. Independent temperature limit alarm system, which automatically interrupts when the temperature limit is exceeded. 4. The use of door temperature control can effectively prevent condensation on the glass door inside the box.
CO2 incubatorPrecautions for use
1. Before filling the CO2 incubator with water, the power switch cannot be turned on, otherwise the heating element will be damaged. 2. After running the incubator for several months, the water in the tank may decrease due to evaporation. When the low water level indicator light is on, water should be replenished. First, open the overflow pipe and use a funnel to connect the rubber tube to add water from the injection hole to turn off the low water level indicator light. Then, measure the amount of water added and block the overflow hole. 3. The CO2 sensor is calibrated under saturated humidity, so the humidification disk must always be filled with sterile water. 4. Try to minimize the time it takes to open the glass door. 5. When cleaning the incubator workshop, do not collide with components such as sensors, mixing motors, and wind turbines. 6. When disassembling and assembling the bracket cover in the workshop, a random wrench must be used and excessive force must not be applied. 7. Before transporting the incubator, the water inside the incubator must be drained. When draining, the rubber tube should be tightly fitted onto the water outlet hole, so that the pipe mouth is lower than the instrument. Gently take a sip, lower the water pipe, and the water will be siphoned out. 8. Before moving the incubator, the shelves and humidification tray inside the studio should be taken out to prevent collision and damage to the glass door. 9. When transporting the incubator, do not invert it and do not lift the door to avoid deformation.