Precautions for using high and low temperature all-in-one machines
Date: 2025-12-22Read: 0

highLow temperature integratedMachine is a type ofCollecting refrigerationAnd heatingIntegrated functionalityequipmentWidely used inLaboratoryIndustrial and other fieldsTo ensuresafetyuseAnd extend itEquipment lifespanHere iskeyNotes:

1. Installation and Environmentrequirement
improve air circulationheat dissipationensureSurrounding the equipmentThere is enoughSpace(Suggestion ≥50cm),Avoid blockagein and outWind vent,防止overheatingorheat dissipationbad.
environmenttemperature: Workambient temperatureusuallysuggestionIn 5~30Between ℃, too highOr too lowpossiblyaffect performance.
power supplystable: Usematchthe power supplyVoltage(Like 22010%), GroundingreliableTo avoidandbigPower equipmentShared circuit.
horizontally placedEquipment requiredStable placementTo avoidtiltorvibration, 防止compressordamage.

2.operationPrecautions
startpre-check
confirmpipelineSecure connectionleak-freeespeciallyCirculating mediumpipeline).
Check cycleMedium(Like siliconOilWater)liquidIs the position correctInnormal range, insufficientTime requiredSupplement.
Temperature setting
avoidsharptemperature differenceChange,It is recommended to5~10℃/Min'sratelifttemperature防止thermal shock.
High temperature(150℃)orLow temperature(40℃)Run time, need toPreheat in advance/precoolingequipment.
runChinesemonitor
observepressure gaugeCurrentIs the table okaynormalAbnormal noiseOr call the policeImmediate action is requiredStop the machine.
high temperatureruntimeDo nottouchExportpipeline, 防止scald.

3.maintenanceAnd maintenance
regular cleaning
monthlyClean and dissipate heatfilterThe internet,Prevent dustpile upAffects heat dissipationEfficiency.
condensationEquipment(windCold/water cooling)Need toRegular dust removalOr checkwaterwayunimpeded.
Media replacement
cycleMedia based onfrequency of useregularlyReplace(Like siliconOil per6~12 months)To avoidOxidation orpollution.
During low-temperature operationEnsure thatLow temperature mediumstickyAppropriate degree(such asuselow temperatureSpecialized SiliconOil).
systemcheck
quarterlyCheck the compressorlubricating oilstateIf necessarySupplement orreplace
checkelectricallinepresence or absenceAgingLoose.

4. Safety Warning
antifreezeAnti boiling
low temperatureruntimeEnsure thatenvironmenthumiditylow, 防止pipelinefreeze; High temperatureWhen avoidingMedium vaporTransform.
urgentsituation
Encountering leakage, MaoSmoke orabnormalcall the policeImmediatelypower outageAnd contactprofessional.
Do not do it yourselfDisassemble the compressorOr refrigerationcomponentMay containHigh pressure coolingMedia).
protective measures
high temperature/Low temperature cycleWhen,Wear insulationGlove operationAvoid direct contactcontactTemperature components.

5.long-termdeactivatehandle
rowEmpty cycleMedium,Clean the interiorpiping,Prevent residuecorrosion.
disconnectPower Supply,coverEquipment defenseDust,Electricity supply every month1Next time(30Minutes)To maintaincircuit.

6. Other suggestions
according tomanufacturermanualOperation,different modelspossiblyspecialrequirement
complexfault(such asRefrigeration efficiencydeclinetemperature controlNot allowed)suggestionContact after-sales servicerepair.