Welcome Customer !

Membership

Help

Guangzhou Dejun Instrument Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>News

Guangzhou Dejun Instrument Co., Ltd

  • E-mail

    1067173170@qq.com

  • Phone

    18122351750

  • Address

    Room 2519, Jinhui Building, No. 123 Jiefang South Road, Yuexiu District, Guangzhou City

Contact Now
Emergency Monitoring of Naphtha Leakage - Portable Emergency Oil Meter TD-560
Date: 2019-07-15Read: 0

Yichuan County promptly dealt with a naphtha leak incident
Release time: June 26, 2019 01:52 Source: Office of Yichuan County People's Government 【 Font: Large, Medium, Small 】 Print and save


At 5:36 am on June 25, 2019, a naphtha tanker truck accidentally collided with a lighting station in the Hukou service area of Qinglan Expressway (Yichuan section), causing the pipeline and connection under the tank to tear, resulting in naphtha leakage and some flowing into Shiwang River.
After the incident, the Yichuan County Party Committee and County Government attached great importance to it, immediately activated the emergency plan, established an emergency response leadership group, and organized personnel to carry out disposal work. Mobilize sprinkler trucks to spray and atomize the site, transport sand to cover the leaked naphtha, dig anti-seepage pits and build dams in the Shiwang River section, transport emergency supplies such as oil absorbing felt, oil absorbing cotton, activated carbon to degrade and adsorb pollutants, and arrange personnel to monitor the water quality of the Shiwang River 24 hours a day.

Naphtha is one of the petroleum products, also known as chemical light oil. It is a light oil produced by processing crude oil or other raw materials for chemical raw materials, mainly used for reforming and chemical raw materials. Due to different purposes, there are various distillation ranges, and China stipulates that the distillation range is from the initial boiling point to around 220 ℃. When used as a reforming raw material for the production of aromatic hydrocarbons, a 70 ℃~145 ℃ fraction is used, which is called light naphtha; When producing high octane gasoline, use 70 ℃~180 ℃ distillate and weigh naphtha; When used as a solvent, it is called solvent naphtha; Aromatic solvents from coal tar are also weighed as naphtha or solvent naphtha.

Emergency oil analyzer

Turner, USATD-500DPortable water oil analyzer is a UV fluorescence oil analyzer that uses n-hexane as an extractant, which can quickly, accurately, and reliably measure petroleum in water(Crude oil, diesel, fuel oil, lubricating oil, condensate oil and refined hydrocarbons, light mixed oil)The range is0.005~1000mg/LAccuracy and repeatability±2%It can be used for both emergency monitoring of oil spills in the field and routine water sample analysis in the laboratory.

1Introduction to the instrument:

Turner, USATD-500DPortable water oil analyzer is a UV fluorescence oil analyzer that uses n-hexane as an extractant. It can quickly, accurately, and reliably measure petroleum products (crude oil, condensate oil, diesel, lubricating oil, fuel oil, engine oil, and other refined hydrocarbons) in water, with a range of0.005~1000mg/LAccuracy and repeatability±2%.

TD-500DThe advantages of small size, high accuracy, easy operation, and safe extraction agent make it suitable for both emergency monitoring of oil spills in the field and routine water sample analysis in the laboratory. Widely used in petroleum and petrochemical industries (oil fields, offshore oil platformsFPSOIn the fields of oil refineries, petrochemical plants, steel, as well as environmental protection and monitoring, hydrology and water conservancy, oil and ocean bureaus, maritime bureaus, boiler special inspections, etc.

2Application:

nproduced water/Reinjection water;

nrecirculating cooling water/Condensate water;

nIndustrial wastewater/Wastewater;

nsurface water/groundwater/海水;

nEmergency monitoring of oil spills in the field;

nOil analysis in soil;

3Performance characteristics:

  • Advanced UV fluorescence method: accurate, sensitive, and reliable;
  • A/BDual channel dual range design, expanding range(0.005~1000mg/L)
  • N-hexane rapid extraction method, replacing infrared method for high efficiency*Highly polluted tetrachloride*Extraction agent;
  • Certified petroleum reference materials with commercially available n-hexane system(HJOil standard);
  • Small size, easy to operate, suitable for emergency monitoring of oil spills in the field;
  • CheckPointSolid calibration samples, convenient for rapid calibration and data verification in the field, without the need for calibration solutions;
  • Measurement results andHJ 970-2018UV spectrophotometry andHJ 637-2018Infrared spectrophotometry has good correlation.

Turner, USATD-550TheTD-560The water oil analyzer is a newly launched product forN-Hexane as a Substitute for Infrared Tetrachloride*Portable extractant&Laboratory combined fluorescence oil analyzerQuick oil analyzer, capable ofQuickly and reliably detect oil content (petroleum) in water, with a measurement range of0.005~5000mg/LAccuracy and repeatability±2%It can be used for both emergency monitoring of oil spills in the field and routine water sample analysis in the laboratory.

Instrument Introduction:

Turner Hydrocarbon Instrument Company, USA(Turner Designs)Focusing on oil analysis in water30In the year, a new industry product, UV fluorescence oil analyzer, was launchedTD-550andTD-560.

Turner, USATD-550TheTD-560Water oil analyzer, is a device used forN-Hexane as a Substitute for Infrared Tetrachloride*Portable extractant&Laboratory combined fluorescence oil analyzerQuick oil analyzer, capable ofQuickly and reliably detect oil content (petroleum) in water.

TD-550Suitable for detecting crude oil, marine diesel, heavy fuel oil, and other heavy oils in water, with a significantly expanded detection range(5ppb~5000ppm)Its performance surpasses that of most water oil analyzers.

TD-560Equipped withTD-550On the basis of the same optical channel, add a second optical channel for detecting light hydrocarbons. The added oils include: condensate oil, diesel, gasoline, lubricating oil, aviation fuel, kerosene, transformer oilBTEXBenzene derivatives, styrene, phenol, etc.

Based on our portable technologyTD-500DAnd desktopTD-3100Successful experiences on products, new onesTD-550andTD-560The product includes various new features and performance that traditional water oil analyzers have never provided, while providing customers with a low-cost, safe, reliable, and simple solution for measuring oil (petroleum) in water.

Application scope:

1Field emergency monitoring;

2Routine laboratory analysis.

Applicable water samples:

produced water/Reinjection water, circulating cooling water, steam condensate (condensate), industrial wastewater, water treatment effect verification, discharge compliance monitoring, rainwater and accident wastewater, surface water/groundwater/Analysis of oil in seawater, soil, and various other water samples.