In the hot summerXenon lamp aging test chamberThe most common ones are over temperature, over pressure, and overload alarms, and the most effective maintenance method is to install air conditioning in the laboratory; So, as the seasons change, how should we maintain it in the cold winter?

2.jpg

1. Installation site for xenon lamp aging test chamber: In dry, rain and snow free areas, air conditioning can also be installed like in summer, and steam tracing measures such as pipe steam heating can be used for insulation; Before winter insulation and steam supply, check whether the steam insulation pipeline is unobstructed or blocked;

2. It is recommended to use high-purity refrigerant. If the refrigerant is filled with too much moisture, it will cause ice blockage;

3. Check and maintain the water storage inside the humidifier, which should be replaced once a month to ensure the cleanliness of the water quality. The humidification water tray should be cleaned at least once a month to ensure smooth water flow;

4. Check if the drying filter is aging. If aging occurs, it needs to be replaced in a timely manner, otherwise its proper drying and water absorption function will cause freezing; Here, the editor can also teach you a method to make your own dry filter;

Find an iron can with a sealed lid, drill a 6-centimeter circular hole at the bottom of the box, weld a section of copper pipe at the circular hole, and put about 200 grams of dry calcium chloride (choose a large piece) made (depending on the effective volume of the iron can) into a thick nylon cloth bag. Place it in the iron can and cover it tightly. When not in use temporarily, plug the two pipe openings firmly to prevent humid air from entering. When in use, remove the plug and connect the exhaust port to the compressor intake pipe. After use, be sure to seal both pipes tightly.

I hope these methods provided by the editor can be helpful to you in the upcoming winter. Additionally, we can protect some areas that require anti freezing measures with insulation materials, but it is important to ensure good ventilation performance of the xenon lamp aging test chamber.