E-mail
apkjcss@foxmail.com
-
Phone
18033338362
-
Address
Building B, Qianhong Industrial Park, No. 53 Wanbu Road, Changping Town, Dongguan City
Guangdong Aipei Testing Equipment Co., Ltd
apkjcss@foxmail.com
18033338362
Building B, Qianhong Industrial Park, No. 53 Wanbu Road, Changping Town, Dongguan City
08.17,20220
1、 Original equipment nameProgrammable Xenon Lamp Weathering Test Chamber (Water Cooled)
2、 Model numberAP-XD-500S
3、 Equipment usageThis product is a test equipment that uses xenon arc lamps as light sources to simulate and enhance weather resistance and accelerate aging, in order to quickly obtain near atmospheric aging test results and evaluate the weather resistance of materials. Weather resistance testing is an important means of screening and optimizing product composition in the scientific research and production process, and it is also an important part of product quality inspection. Materials such as coatings, plastics, aluminum-plastic panels, and automotive safety glass are required to undergo weather resistance testing according to product standards.
4、 Sample limitationsThis experimental equipment prohibits:
1. Testing or storage of samples of flammable, explosive, and volatile substances
2. Testing or storage of corrosive substance samples
3. Testing or storage of biological samples
4. Testing or storage of strong electromagnetic emission source samples
5. Testing or storage of radioactive material samples
6. Testing or storage of highly toxic substance samples
7. Testing or storage of samples that may produce flammable, explosive, volatile, highly toxic, corrosive, and radioactive substances during the testing or storage process.
5、 Volume, size, and weightNominal internal volume: 512L.
Box dimensions in the testing area: W (800) mm × H (800) mm × D (800) mm.
The overall dimensions of the machine are approximately W (1300) mm × H (2200) mm × D (1200) mm.
Weight: Approximately 350KG

VIWater cooled Xenon Lamp Weathering Test Chamberperformance
6.1 Test Environment ConditionsThe ambient temperature is+5~+28 ℃, and the relative humidity is ≤ 85%.
6.2 Testing MethodsNational standard GB/T16422.2, American standard AATCC TM16 ASTM C1442.
6.3. Xenon lamp powerLong arc xenon lamp, 6KW X (1)
6.4. Xenon lamp wavelength290~800nm
6.5. Radiation intensity550W/m2 adjustable
6.6. Radiation intensity adjustmentMicrocomputer+PID+digital power supply+xenon lamp infinite adjustment
6.7. Radiation intensity measurementEquipped with a sun eye, it automatically measures and controls the irradiance value set by the user
6.8. Filter
S1 high-purity quartz glass ensures that the spectral cutoff value of irradiance on the sample is similar to that of ground sunlight.
Modular design allows for optimized combinations based on testing space, making it very convenient to replace light tubes.
Depending on the environment, you can choose to simulate direct sunlight or sunlight transmitted through window glass.
Unless the filter is damaged, there is generally no need to replace the filter.
6.9. Blackboard (BPT) or black label (BST) temperature: adjustable from room temperature+10 ℃ to 100 ℃.
6.10. Temperature degree±3.0℃
6.11. Humidity RangeThe exposure period can be adjusted from 10% R.H to 70% R.H. The dark period is adjustable from 20% R.H to 98% R.H.
6.12. Humidity level±5.0 %R.H。
6.13. Dark cycle and irradiation cycleAdjustable from 0 to 9999H
Usage steps
1. Place the sample on the test rack inside the box.
2. First, turn on the "main power" on the back of the device, and then turn on the "power on" button on the panel.
3. Adjust the temperature and humidity, test time, and lighting time for the experiment.
① Adjust temperature and humidity: Press the "SET" button lightly to change the test parameters through "human" and "one".
② Adjust the test and lighting time: Remove the organic glass cover on the time display and use the "top" and "bottom" keys to change the size, with the middle key being the time key.
4. Before turning on the light, turn on the "Xenon Lamp Preparation" and then "Light Up". If you need a light cycle, turn on "Light Up" again (note: if you need to do any experiment, just light it up).
5. After the experiment is completed, all buttons should be turned off.
6. Open the box door and take out the test sample to check its quality.
Precautions for using xenon lamp weathering aging test chamber
1. During operation, please do not open the box door unless necessary, as it may lead to adverse consequences.
2. To provide safety protection for the testing products and operators of this machine, please regularly check the water pressure controller and circulating water tank water level.
3. Correctly installing the wet bulb test cloth is necessary to ensure accurate measurement of relative humidity.
4. Please read this manual carefully before operating this machine. Xenon lamp aging test chamber applicable industries
1. Automobiles and motorcycles: People place them outdoors, so the exterior of cars needs to undergo a light test to see if the material of the exterior will age and peel off paint over time under light.
2. Building materials can be divided into structural materials, decorative materials, and certain specialized materials. Materials that are exposed to external sunlight for a long time need to be tested for their light resistance using a xenon lamp aging test chamber.
3. Textiles: Simply put, they refer to the clothes people wear, curtains at home, and other items that require light testing to determine if they will fade after prolonged use. Furniture leather: A good set of furniture is believed to be used by a family for 40 or 50 years. Of course, good furniture also needs to be tested, not only for lighting, but also for temperature and humidity, in order to determine whether the sofa will peel off after years of use.
Next Video: Aipei Technology Factory on-site filming video