  Planetary vacuum defoamerThe maintenance points mainly include the following:
Regularly clean the chamber and stirring blade, and promptly clean the residual materials inside the chamber after each use to avoid affecting the sealing and stirring effect after solidification; After disassembling the mixing blade, wipe it with a special cleaning agent to remove any adhering impurities. After drying, reassemble it to prevent scratching the parts.
Check the sealing of the vacuum system regularly and inspect the sealing status of the vacuum pipeline and sealing ring. If the sealing ring is found to be aged, cracked, or leaking, replace or repair it immediately; When idle, a small amount of silicone oil can be applied to the sealing surface to extend the service life of the sealing ring.
Lubricate the transmission components according to the equipment manual cycle, and add specified types of lubricating oil to the planetary transmission mechanism, bearings, and other components to avoid component wear caused by dry friction; Pay attention to the amount of lubricating oil used to prevent excessive overflow and contamination of the chamber.
Regularly disassemble the filter at the vacuum inlet of the cleaning and filtering device, remove dust and impurities from the filter screen, and ensure the efficiency of vacuum extraction; Replace the filter screen in a timely manner when it is damaged to prevent impurities from entering the interior of the vacuum pump and causing damage.
Maintain the electrical control system to keep the control box dry and clean, avoiding the entry of dust and moisture; Regularly check whether the wiring terminals are loose, and whether the sensors, buttons, and other components are sensitive. If any faults are found, stop the machine for maintenance in a timely manner.
When the maintenance equipment is not used for a long time during the idle period, it is necessary to empty the residual materials inside the cavity and keep it dry; Disconnect the power supply, take measures to prevent dust and moisture, and place it in a ventilated and dry environment.