Operation and maintenance of volumetric micro moisture analyzer
Date: 2025-11-16Read: 0
  Volumetric micro moisture analyzerIt can detect moisture in liquids (such as solvents and lubricants), solids (such as drugs and plastic particles), and gases (such as natural gas and inert gases). Some solid samples require auxiliary injection with a heating furnace.
  Volumetric micro moisture analyzerApplication areas:
Petrochemical industry: detect moisture in lubricating oil, transformer oil, diesel, ethylene glycol and other oil products or chemical raw materials to avoid equipment corrosion or performance degradation caused by moisture.
Pharmaceutical industry: Determine the moisture content in drug raw materials (such as antibiotics, vitamins), injection solutions, and capsule shells to meet the requirements of drug quality standards.
Food industry: Analyze the moisture content in solid foods such as milk powder, chocolate, protein powder, or liquid foods such as ethanol and juice to control product shelf life and taste.
Electronics industry: Detect trace amounts of moisture in electronic chemicals and lithium battery electrolytes to prevent moisture from affecting electronic component performance or causing safety hazards.
Materials industry: Determine the moisture content in polymer materials such as plastics, rubber, and resins to prevent moisture from causing bubbles or cracking in products during processing.
Operation process: including sample processing, method setting, titration operation, result processing and analysis, as well as cleaning and shutdown steps. Users need to select or create titration methods based on sample type and analysis requirements, and start the instrument for automatic potentiometric titration testing.
Daily maintenance: After daily inspection, the "emptying pipe" function should be executed to empty the liquid in the pipeline; Rinse the electrode with pure water and soak or dry it according to the instructions for storage; Replace the titration pen promptly when it is worn or contaminated; Check the pump sealing ring every six months to prevent leakage.
Long term shutdown treatment: Disassemble the pipeline and burette to avoid reagent crystallization blockage; Put the instrument into a dedicated box and store it in a cool and dry place.