Pneumatic adjustable angle seat valveIt is inevitable to encounter malfunctions during use. So, how to eliminate this phenomenon? First, analyze the causes:
1. During use, it is necessary to adjust the flow rate, which is controlled by a worm gear box.
2. The installation position in the pipeline is vertical, but cannot be inverted.
3. Check that all connecting parts are tightly pressed to ensure the honeycomb properties of the packing and the flexible rotation of the valve stem.
4. It is recommended to use disc valve flanges for the installation of disc plates to avoid improper use of the product that may cause damage.
5. For ball valves that open and close frequently, after about two months, open the worm gear box cover and check if the butter is normal, and maintain an appropriate amount of butter.
6. . Before installation, confirm whether the product performance and medium flow arrow are consistent with the operating conditions, and clean the inner cavity of the electric control valve and pneumatic angle seat valve. It is not allowed to have impurities or foreign objects on the sealing ring and ball plate. The ball plate must not be closed before cleaning to avoid damaging the sealing ring.
The above is an introduction to the troubleshooting methods for pneumatic regulating angle seat valves.