The use and maintenance of drug shade boxes
Date: 2025-09-18Read: 0
  Drug shade boxIt is a professional equipment specifically designed for storing drugs that need to be stored in an environment of 8-20 ℃ and humidity of 35% -75%. Through high-precision temperature and humidity control, UV protection design, and safety alarm function, it ensures the activity and safety of drugs, and is widely used in pharmacies, pharmaceutical factories, laboratories, and other scenarios.
Features:
Temperature control: A microcomputer temperature control system is usually used, with a temperature control range of 8-20 ℃ and a temperature fluctuation of ≤± 2 ℃, which can accurately maintain the temperature stability inside the box and meet the requirements of most cool storage drugs.
Refrigeration system: Fully enclosed compressors are commonly used, combined with high-efficiency air duct systems, which have high refrigeration efficiency and functions such as compressor overheating, overpressure, overload protection, etc., with stable and reliable performance.
Security system: Equipped with a comprehensive sound and light alarm system, it can promptly issue an alarm when the temperature and humidity exceed the set range or when the equipment malfunctions, ensuring the safety of drug storage. Some parts can also be equipped with remote alarm and data recording systems.
Usage and maintenance matters:
Daily use: should beDrug shade boxPlace in a well ventilated area, away from direct sunlight, with appropriate space around for heat dissipation. Regularly check the operation status of the equipment daily, including temperature display, cooling effect, cabinet door sealing, etc., and keep records. When opening or closing the cabinet door, the action should be rapid to minimize temperature fluctuations inside the cabinet.
Cleaning and maintenance: Regularly clean the dust and debris inside the box. When cleaning, turn off the power first and use a clean damp cloth to wipe the inner surface. Clean the appearance of the box every month, check whether the sealing strip of the cabinet door is intact, and replace it in a timely manner if there is aging or damage.
Performance inspection: Check the refrigeration system quarterly and clean the dust on the surface of the condenser and evaporator. Calibrate the temperature control system every six months, check the working parameters of the compressor and electrical system.