HT-TA026 Trace Oxygen Transmitter
Date: 2020-09-02Read: 2

HT-TA026 Traceoxygentransmitter(Glove box)

Technical Specifications:

  • Measuring principle:Ion flow(Limit current)
  • display mode:high-resolutionRate LCDdisplay
  • measurement range:0~10/100/1000ppm O2
  • measurement accuracy:0~1000ppm≤±1%FS

0~100ppm≤±2%FS

0~10ppm≤±3%FS

  • Display resolution:0.1ppm
  • Repeatability:≤±1%FS
  • response time:T90≤15S
  • outputinterface:4-20mA. DC(Non isolated output, load resistance less than 500 ohms)
  • contact method:RS485
  • power supply:DC24V±10,200mA
  • environmenttemperature-10 ~+60℃
  • Storage environment humidity:<90%RH, non condensing
  • Working environment humidity:<100%RH, non condensing
  • Sample gas temperature: 0 ~ 50℃
  • sampling method:Insertion type(Free diffusion)
  • enterBarometric force:95kPa~105kPaStable pressure atmosphereControl the pressure within the specified range to ensure that it can provide400~600mL/min flow rate is sufficient)
  • Background gas:N2or otherInertMixed gases such as sexual gases
  • service life:>60 of themMonth (under normal usage conditions)
  • Installation method:KF40Flange installation

Instrument features:

  • highResolution LCD display screen, DisplayClear and beautifulObservation;
  • Adopting * limit current sensor, withFast response speed、High measurement accuracy and long calibration cycleOther characteristics;
  • sensorhaveWithout power, it does not consume lifespan. The transmitter is equipped with an automatic sensor protection function, which automatically shuts down when the sample gas concentration is too high;
  • Menu locking function to prevent misoperation from changing instrument parameters and affecting its performance;
  • temperatureAnd pressureCompensation,Eliminate temperature and pressure effectsThe impact of measurement accuracy;
  • Compact and beautiful appearanceStructural Design*;
  • KF40 flange installation, easy to install;
  • Measurement range: 0.1ppm~1000ppm O2;
  • The instrument can test both trace oxygen in nitrogen and trace oxygen in argon.

Application scenarios:

Glove boxes can also be used for online analysis of trace oxygen in mixed atmospheres of oxygen, nitrogen, and inert gases such as air separation and protective atmosphere furnaces.

Ordering Instructions(Please specify when placing an order)

  • Instrument measurement range
  • The background gas is N2or othernoble gas