HT-LH303 flue gas humidity transmitter
Date: 2020-09-23Read: 3

HT-LH303 flue gashumidity transmitter

Technical characteristics:

  • Measurement principle:capacitive
  • Display mode:128×64dot matrixOLED
  • Measuring range:Volume humidity:0 ~ 40.0%VOL

qualityhumidity:0 ~ 400g/m³

relative humidity:0 ~ 100%RH

High temperature dew point:-20 ~+100℃

(Only one mode can be displayed,When placing an orderPlease addExplanation)

  • Measurement accuracy: ≤±1.5%FS
  • resolution:high temperaturedew point0.1℃Relative humidity and humidity0.1%
  • Repeatability: ≤±1%FS
  • Response time:T90≤15S
  • analog output:4-20mA. DC(Non isolated output, load resistance less than500Ohm)

1Programmable dry contact type passive alarm output,Large contact capacity220VAC/2A

  • contact method:RS232(default) orRS485
  • working power supply:12~32VDC /500mA
  • Sample gas temperature:0~170℃
  • ambient humidity:<80%RH

lsampling method:in situformula

  • Sample gas groupcopy:No flammable gases, no highly corrosive gases
  • Sampling interface:Φ 6 stainless steel card sleeve (316L)
  • Specifications and Dimensions:instrument63mm×150mm×105mm(H×W×D)
  • installation dimensions:133mm×48mm(W×D)
  • service life>24moon(Under normal usage conditions)
  • Installation method:wall-mountedformula(instrumentpart)

Instrument features:

  • highlightOLED active light-emitting display, intuitive display;
  • volumeHumidityqualityhumidity、Relative humidity, high temperature dew pointfourSwitch display modes freely;
  • *Sensor chips can effectively ensure instrument accuracy and service life;
  • Internally equipped with temperature compensation function, reducing the impact of temperature changes on humidity measurement accuracy.

Application scenarios:

widely used inonlineflue gasdetectionCEMSdesulfurizationHumidity and dew point in equipment, power plants, and other placesMeasurement and analysis.

Ordering Instructions(Please specify when placing an order)

  • measurement range
  • display mode(volumeHumidityqualityhumidity、Relative humidity, high temperature dew point)Can only be displayed simultaneouslyoneVarious modes