PHP-FB Wind Speed Alarm Device
PHP-FB Wind Speed Alarm DeviceOverview
According to the technical requirement 4.1.2.1 of the "Tower Crane Design Specification Standard JB9462-88" issued by the Ministry of Construction, the wind speed should not exceed 20m/s when working at the maximum installation height of the crane. The overall installation climbing or jacking operation wind speed shall not exceed 13m/s. ”According to Article 4.5.6, for cranes with a total intersection point of more than 50m at the base of the boom, an anemometer should be installed at the top. ”(2) The Tourism Bureau has designed and manufactured the regulations on the operation of passenger aerial ropeways in abnormal weather conditions, which stipulate that the operation must be stopped when the maximum instantaneous wind speed exceeds 15m/s.
Technical performance indicators
| Starting wind speed | 0.4m/s |
| measurement range | 0.4~70m/s |
| resolution | 0.1m/s |
| measurement accuracy | 0.4+2% x actual wind speed |
| sampling time | 3 seconds |
| alarm method | audible and visual alarm |
| display | Dual screen display, high brightness digital tube displays wind speed (m/s), LCD screen displays menu |
| power supply | 220VAC 50Hz |
| Usage environment | Host temperature: -10~50 ℃; Humidity: 20% to 90% RH; Probe temperature: -22 ℃ to+50 ℃ |
| Alarm relay output capacity | 1A 220VAC |