Function and operating specifications of the constant temperature cultivation shaker under illumination
Date: 2025-04-25Read: 1
Light controlled constant temperature cultivation shakerIt is an experimental equipment widely used in the fields of biology, medicine, and laboratory research, used to provide constant temperature and light conditions to promote the growth and cultivation of organisms. It is used in experimental scenarios such as microbial culture, plant tissue culture, algae culture, and biological fermentation that require synchronous control of light and oscillation.

Function:

1. Temperature control

By using a microcomputer intelligent control system and high-precision sensors, a wide temperature range of 4 ℃ to 60 ℃ can be achieved with small temperature fluctuations. The temperature distribution inside the box is uniform to avoid local temperature differences affecting the experimental results.

2. Lighting system

Adopting LED bio light source, supporting 0-16000LX stepless adjustment, stable spectral characteristics, low heat generation, suitable for photoperiod experiments. The light intensity can be pre-set into multiple programs, allowing for free combination of day and night for 1-24 hours, simulating natural light environments.

3. Oscillation function

Provide two oscillation modes, reciprocating and swirling, to meet different needs such as cell culture and enzyme reactions.

Light controlled constant temperature cultivation shakerOperating standards:

1. Installation and Debugging:

The equipment should be placed on a flat, dust-free, and electromagnetic interference free tabletop, with a distance of ≥ 10cm from the wall and good ventilation.

*Preheat for at least 30 minutes before use to ensure accurate calibration of the temperature sensor.

2. Experimental procedure:

When bottling, place symmetrically or add an equal amount of solution to avoid unbalanced vibration; Adjust the oscillation speed slowly to the set value.

Observing the situation inside the box can be done through tempered glass windows or lighting switches to avoid frequent lid opening and temperature and humidity fluctuations.

3. Parameter settings

Temperature setting: Use the "Settings Measurement" switch to switch modes and adjust the temperature control knob to the target value.

Light adjustment: Select the light intensity and time program according to the experimental requirements.