Analysis of Verification Results for Residual Detection Ability of β - Receptor Agonists in Pig Liver
The Veterinary Drug Supervision Institute organized and implemented residual detection of three receptor agonists, namely clenbuterol, salbutamol, and ractopamine, in pig liver
Ability verification work for testing. A total of 68 laboratories from 22 provinces, municipalities, and autonomous regions across the country participated in this proficiency test, using the following tests
The main methods are liquid chromatography-mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS). The results show that:
The laboratory satisfaction rates for clenbuterol, salbutamol, and ractopamine were 7.7% 8%, 89.6%, and 92.2%, with suspicious result rates of 11.1%, 4.17%, and 0%, respectively. The unsatisfactory result rates were 11.1%, 6.25%, and 7.84%, respectively