incubatorAfter a malfunction occurs during use, users may feel confused and unsure of the cause. Despite following the instructions, the problem still occurs during use. The reason for this may be that we overlooked some details when using the incubator. As a user of incubators for many years, we have summarized the following details that equipment users need to pay attention to.
1. FirstlyincubatorIt should be placed on a flat ground. If the ground is uneven, we should level it. We place the equipment in an environment with a room temperature below 30 degrees Celsius. If the equipment is used above 30 degrees Celsius, it is recommended to install ventilation facilities at the back of the equipment or install it in a place very close to the air conditioner. This can prevent the compressor from overheating and causing the equipment to freeze and lose control of temperature.
2. To avoid damage to the instrument, it is strictly prohibited to put flammable and volatile substances into the biochemical incubator.
3. If you want to move the incubator, it should also be tilted at an angle of 45 degrees or less, and it is forbidden to place it upside down.
4. The incubator should be kept away from electromagnetic interference and must be grounded.
5. When using the incubator, do not place too many items inside the incubator. Ensure that there are air ducts between the items inside the incubator to maintain air circulation.
6. If lighting is not needed, the lights should be turned off to increase the usage time of the lamp tube and ensure that the temperature on the upper layer is not too high.
7. When there is an odor and smoke in the incubator during use, it is necessary to turn off the power in a timely manner and seek professional maintenance personnel for repair and treatment.
8. In order to keep the walls and inner container clean, it is necessary to regularly clean them with clean water and avoid using corrosive solutions such as acid and alkali.
9. If the incubator is not used for a long time, be sure to unplug the power and avoid placing it in a damp place. Then, conduct a conditional operation once every quarter.
10. IfBiochemical IncubatorIn case of moisture, simply pour out the water from the bottom water tray inside the box, set the temperature to 42 degrees Celsius, and run for five hours. Open the box door every two hours to release the moisture, and then unplug the power plug.