An enzyme-linked immunosorbent assay (ELISA) reader is a precision optical instrument, so a good working environment not only ensures its accuracy and stability, but also extends its service life. The routine maintenance process of the enzyme-linked immunosorbent assay (ELISA) reader is as follows:
1The instrument should be placed below40In a decibel environment.
2To delay the aging of optical components, direct sunlight should be avoided.
3The ambient temperature during operation should be within15℃-40Between ℃, the environmental humidity is15%-85%between.
4The operating voltage should be kept stable.
5The operating environment should have clean air and avoid water vapor and smoke.
6Maintain a dry, clean, and level workbench, as well as sufficient operating space.
Operation precautions :
The function of an enzyme-linked immunosorbent assay (ELISA) reader is to read the reaction results of an ELISA kit. Therefore, in order to obtain accurate results, the use of the kit must be standardized. Many hospitals judge the results visually before using an enzyme-linked immunosorbent assay (ELISA) reader, and the operation process is highly arbitrary. If the operating habits are not corrected in a timely manner after using the ELISA reader, it can cause significant errors. Attention should be paid to the following during the operation of the enzyme-linked immunosorbent assay (ELISA) readermatter:
1Use a liquid dispenser to add liquid, and do not mix the liquid heads.
2Wash the board thoroughly. If conditions permit, use a board washing machine to wash the board and avoid cross contamination.
3Strictly follow the instructions of the reagent kit for accurate reaction time.
4During the measurement process, do not touch the enzyme-linked immunosorbent assay (ELISA) plate to prevent the operator's hands from being crushed during the transfer of the ELISA plate.
5Do not spill samples or reagents on the surface or inside of the instrument. Please wash your hands after completing the operation.
6If the samples or reagents used have pollution, toxicity, and biological hazards, please strictly follow the operating instructions of the reagent kit to prevent damage to the operators.
7If the instrument has come into contact with contaminated or infectious substances, please clean and disinfect it.
8Do not turn off the power during the measurement process.
9For the deviation of measurement results caused by reagent kit problems, parameters should be modified in a timely manner according to the actual situation to achieve the best resultseffect.
10Cover the dust cover with a back cover.
11When there is a technical malfunction, it should be promptly reported to the manufacturer and the enzyme-linked immunosorbent assay (ELISA) reader should not be disassembled without authorization.