Welcome Customer !

Membership

Help

Beijing Putian Tongchuang Biotechnology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Article

Beijing Putian Tongchuang Biotechnology Co., Ltd

  • E-mail

    3032079623@qq.com

  • Phone

    13810166850

  • Address

    Tangli Road, Chaoyang District, Beijing

Contact Now
Specializing in rules and precision | Putian Tongchuang launches image measuring instrument Ec calibration dedicated step gauge
Date: 2025-11-24Read: 1

To meet the increasing demand for accuracy and efficiency in the calibration of image measuring instruments, Putian Tongchuang has officially launched a dedicated step gauge for Ec calibration of image measuring instruments. This step gauge is a standard instrument that complies with the JJF 1318-2011 Calibration Specification for Image Measuring Instruments. The main purpose is to calibrate the consistency (Ec) of the measurement results of the image measuring instrument at different cross-sections (Z-axis heights), effectively evaluate the indication error of the instrument in the entire measurement space, and is a key tool to ensure the accuracy performance of the instrument.

专于规,精于准 | 普天同创推出影像测量仪Ec校准专用台阶规


Product Core Value:

Strict compliance: The design and manufacturing comply with the requirements of JJF 1318-2011 Calibration Specification for Image Measuring Instruments, eliminating doubts about the applicability of the standard during the calibration process.

Convenient and efficient: equipped with embedded positioning targets, making the target search and positioning during the calibration process fast and intuitive.

专于规,精于准 | 普天同创推出影像测量仪Ec校准专用台阶规

This product is manufactured with precision according to the following technical requirements.

1. Technical requirements for specialized step gauge substrate:

total length Not less than 4/5 of the diagonal of the working stroke of the measured image measuring instrument
Height difference between two steps Not less than 1/2 of the instrument's Z-axis travel
width Not less than 50mm
Bottom flatness ≤ 0.01mm (concave)
Flatness of the step surface at the groove ≤ 0.005mm

2. Requirements for Embedded Target Technology:

Bottom flatness ≤ 0.005mm
Marking width ≤ 0.005mm

The Ec calibration specific step gauge launched by Putian Tongchuang is not only a product, but also a reflection of our commitment to providing professional, reliable, and efficient measurement solutions for the industry. We believe that it will become a valuable tool for you when performing Ec calibrationCommonly used and professionally reliable assistance.