1. Be careful and cautious when using laboratory equipment.
2. All instruments and equipment in the laboratory shall not be dismantled without permission. Equipment accessories shall be specially matched and used for other purposes, and shall not be dismantled or carried outdoors.
3. It is strictly prohibited to connect power sources privately, and any electrical equipment and power sources in the laboratory must not be touched or tampered with at will to prevent electric shock.
4. After completing the experimental operation, check the doors, windows, water, electricity, and gas before leaving the laboratory.
5. If the fuse blows after connecting the power supply, the cause of the fault must be checked and the obstacle must be eliminated before reconnecting the power supply.
6. No instrument or electrical appliance shall be used without prior knowledge of its usage
7. In the event of an accident during the experiment, do not panic and immediately disconnect the power supply. Report to the management personnel for inspection and handling in a timely manner.
6、 Laboratory Management System
Management System for Flexible Electronic Device Laboratory
In order to standardize the management of relevant laboratories of Hunan Advanced Sensing and Information Technology Innovation Research Institute, ensure the normal operation of laboratories and equipment, achieve expected experimental results, cultivate good experimental habits, and form a rigorous and scientific attitude, the following rules are formulated, and laboratory personnel must strictly follow the rules.
1. Laboratory equipment should be used carefully and cautiously, and should not be used without familiarizing oneself with its usage methods.
2. All instruments and equipment in the laboratory shall not be dismantled without permission. Equipment accessories shall be specially matched and used for other purposes, and shall not be dismantled or carried outdoors.
3. It is strictly prohibited to use computers configured with instruments and equipment for internet access and all other entertainment, audiovisual activities; Do not disassemble or install computers without authorization, and do not rewrite instrument software programs.
4. It is strictly prohibited to connect power sources privately or touch any electrical equipment and power sources in the laboratory with wet hands to prevent instrument damage and electric shock hazards.
5. Experimental personnel must be familiar with the experimental content, operating procedures, and the performance of various instruments before the experiment, strictly follow the operating procedures, and take necessary safety precautions.
6. It is strictly prohibited to conduct experimental operations in this laboratory that contain flammable, explosive, highly toxic, highly irritating, highly corrosive and other hazardous reagents.
7. During the experimental operation, experimental operators are not allowed to leave the laboratory without authorization.
8. It is strictly prohibited to receive visitors, make noise, or engage in any activities unrelated to experimental research in the laboratory.
9. In case of unexpected situations during the experiment, do not panic and immediately turn off all types of hazards (power, gas, etc.) while ensuring personal safety, and promptly report to the management personnel for handling.
10. After the experimental operation is completed, the table and floor should be cleaned in a timely manner to maintain the cleanliness of the laboratory; Before leaving the laboratory, check the relevant instruments and the doors, windows, water, electricity, and gas of the entire laboratory, and ensure that they are closed properly.
543 Laboratory
1、 Personality Laboratory Name: Chemistry and Biosensing Laboratory
3、 Overall introduction to the functions of the personality laboratory:
Function: The laboratory focuses on key technical issues in biosensing, combines cutting-edge disciplinary development and research institute development needs, based on modern analytical chemistry, and conducts research on in vitro diagnostic and monitoring technologies such as biochemical analysis and sensing, bioelectronic devices, etc. through the design of functional materials, biochemical sensitive interface regulation, and signal conversion and transmission.
4、 Main equipment pictures and functional introductions in the laboratory: microelectronic printer, contact angle tester, electrochemical workstation, photoelectrochemical tester, inverted microscope, LCR digital bridge, homogenizer, high-speed centrifuge, freeze dryer.
5、 Laboratory Safety Regulations
1. Flammable, explosive, hazardous materials, storage, and inbound/outbound must be registered.
2. It is strictly prohibited to use electricity without authorization, smoke and open flames in the laboratory.
3. Non laboratory staff are strictly prohibited from staying in the laboratory.
4. Pay attention to safe use of electricity, do not touch the power supply with wet hands or objects, and cut off the power supply in a timely manner after the experiment is completed
5. When heating or pouring liquids, do not look down at the container to prevent injury caused by splashing droplets. When heating the test tube, do not point the tube towards yourself or others to prevent the medicine from spraying out and injuring people.
6. When sniffing gas, one should maintain a certain distance and slowly fan a small amount of the evaporated gas towards oneself with their hands, without leaning down towards the container and directly sniffing.
7. All experiments involving toxic and volatile gases should be conducted in a fume hood.
8. When taking medication, specialized tools such as spoons should be used to avoid skin damage caused by medication contact. After the experiment is completed, wash your hands thoroughly; It is strictly prohibited to eat or bring utensils into the laboratory.
9. Experimental waste liquid should be classified and recycled, and it is strictly prohibited to pour it into the sewer at will.
10. In the event of an accident during the experiment, do not panic and immediately disconnect the power supply. Report to the management personnel for inspection and handling in a timely manner.
6、 Laboratory Management System
Management System for Chemical and Biosensing Laboratory
In order to standardize the management of relevant laboratories of Hunan Advanced Sensing and Information Technology Innovation Research Institute, ensure the normal operation of laboratories and equipment, achieve expected experimental results, cultivate good experimental habits, and form a rigorous and scientific attitude, the following rules are formulated, and laboratory personnel must strictly follow the rules.
1. The chemical drug counter is dedicated and neatly arranged. Drugs of different properties that can react with each other are stored separately in separate cabinets, and chemical drug containers must have labels.
2. The purchase, requisition, and entry/exit of chemical drugs must be recorded in detail.
3. Experimental personnel must be familiar with the experimental content, operating procedures, and the performance of various instruments before the experiment, strictly follow the operating procedures, and take necessary safety precautions (experimental clothing, goggles, masks, gloves, etc.).
4. When using concentrated acid, concentrated alkali, and other corrosive reagents, be careful to prevent splashing and contact with the skin.
5. When heating or pouring liquids, do not look down at the container to prevent injury caused by splashing droplets. When heating the test tube, do not point the tube towards yourself or others to prevent the medicine from spraying out and injuring people.
6. All experiments involving toxic and volatile gases should be conducted in a fume hood; Reagents and drugs cannot be stored for a long time in a ventilated area.
7. When taking medication, specialized tools such as spoons should be used to avoid skin damage caused by medication contact. After the experiment is completed, wash your hands thoroughly;
8. Smoking, eating, and using open flames are strictly prohibited in the laboratory.
9. Pay attention to safe use of electricity, strictly prohibit pulling wires privately, and do not touch the power supply with wet hands or objects. After the experiment is completed, the instruments and equipment should be turned off and the power should be cut off in a timely manner.
10. Experimental waste liquid should be classified and recycled, and it is strictly prohibited to pour it into the sewer without proper treatment.
11. In case of unexpected situations during the experiment, do not panic and immediately turn off all types of hazards (power, gas, etc.) while ensuring personal safety, and promptly report to the management personnel for handling.
12. Before leaving the laboratory, laboratory personnel must check the instruments being operated, as well as the doors, windows, water, and electricity of the entire laboratory, and ensure that they are closed properly.
Product Name |
Technical parameters for bidding |
||||||||||||||||||||
|
ZJ-3Piezoelectric thin filmPVDFtester (*****) |
ZJ-3typePVDFThe piezoelectric tester is designed to measure piezoelectric materialsd33A specialized instrument designed for constants, which can be used to measure piezoelectric ceramics with large piezoelectric constants, piezoelectric single crystals with small piezoelectric constants, and piezoelectric polymer materials. In addition, it can also measure the equivalent piezoelectric properties of piezoelectric single crystals with arbitrary orientations and certain piezoelectric devicesd’33Constant, wide instrument measurement range, fine resolution, high reliability, simple operation, no special requirements for sample size and shape. Circular discs, rings, tubes, blocks, strips, columns, and hemispherical shells can all be measured, and the measurement results and polarity are directly displayed on a three and a half digit panel.ZJ-3 ZJ-3Piezoelectric thin filmPVDFtester The model has added functions such as discharge protection, discharge prompt, and waveform output for the tested components, enabling the instrument to provide high-voltage discharge prompt and protection when measuring non discharged (especially large-sized) piezoelectric components. This instrument is used in the production, application, and research departments of piezoelectric materials and piezoelectric components.
d33Measuring range: ×1Block:10to2000pC/N,20 to4000pC/N, can be upgraded to10000PC/N. matchableD31Block fixture,D15Block fixture,D15Circular tube fixture, thin film stretching fixture Can be matchedPZT-JH10/4/8/12Use of piezoelectric polarization device Can be matchedZJ-D33-YP15Use of voltage sheet machine Measurement calibration standard sample size:18mm*0.8mmAging time:2-3Year (one of the important criteria for evaluating the accuracy and performance of piezoelectric testers) supplementary parameters:
|
||||||||||||||||||||
|
TDZT-04CComprehensive testing system for ferroelectric properties (***) |
TDZT-04CThe comprehensive testing system for ferroelectric properties is the latest generation of ferroelectric material parameter testers suitable for measuring the electrical properties of ferroelectric thin films and ferroelectric materials (both bulk materials). It can measure the hysteresis loop of ferroelectric thin filmsI—VThe characteristics and switching properties of ferroelectric thin films with asymmetric hysteresis loops can be accurately measuredPrValue. The hysteresis loop of measurable ferroelectric materials andI—Vcharacteristic. Main technical indicators: 1.Output signal voltage: Thin film:0~±10VCeramics and materials:0~±2000V 2.Output signal frequency: thin film material1-1000HZCeramics:0-1Hz 3.Capacitor range:1000nf~100nf,precision:≤1%. 4.current range: 1nA~10A ,precision:≤1%. 5Test samples:0-20mm 5a 6High pressure sample cell: open type:8CM*5CM 7Three dimensional mobile thin film testing platform: one set of upright probes 8Current:1-10Magnification, signal:1-20Twice..Data interface:USBorBNCInterface. 9. Data acquisition and analysis software: capable of drawing hysteresis loops of ferroelectric thin films and quantitatively obtaining the saturation polarization of ferroelectric thin film materialsPsRemaining polarizationPrCoercive fieldEcParameters such as leakage current;It can conduct tests on the ferroelectric fatigue performance, ferroelectric retention performance, resistance measurement, and leakage current measurement of ferroelectric thin film materials. 10.Can cooperateZJ-3andZJ-6Operating system of piezoelectric tester |
||||||||||||||||||||
|
PZT-JH30/1typePVDFThin film polarization device (*****) |
PZT-JH30/1Piezoelectric composite polarization device is mainly used for30KVThe following piezoelectric ceramics orPVDFThe polarization treatment of thin piezoelectric materials is widely used in universities and research and production units engaged in piezoelectric material research or production. It can be directly placed on the experimental table for operation, which is convenient and safe. Key Features: 1、 Main features of the product: 1One click operation, digital display, polarization of various PVDF films and piezoelectric ceramics (polymers made from selected combinations of vinylidene fluoride (VDF), trifluoroethylene (TRFE), 1,1-chlorofluoroethylene (CFE), and/or trifluorochloroethylene (CTFE)) 2Output voltage up to 2KV, output power 2W 3Fire protection and short circuit protection, automatic voltage cut-off 4Low temperature coefficient 0.001% per degree Celsius 5Fully digital operation, high efficiency, and good results 6Multiple polarization methods (air, silicone oil, heating) 7External potentiometer or external control voltage setting 8Small size, printed circuit board installation 9Positive or negative polarity output Main technical parameters: 1、 PVDF polymer film samples and PZT piezoelectric ceramic materials 2Regional surface polarization, polarization size: 0-20mm, 3Voltage not less than DC negative pressure polarization 30KV, ambient temperature air polarization, silicone oil, heating in multiple ways 4Working power supply: AC220V 50/60HZ Rated power: 2.0kw 5Polarization or voltage withstand test of piezoelectric materials: DC: 0-30KV (± 5% continuously adjustable) 6Total current: 10mA 7Cut off current for each circuit: 0.5mA 8Standard film samples: 3 pieces of 1CM * 1cm, ceramic pieces: 4 pieces, diameter: 1CM * 1mm 9Timing: 1-99min ± 5% can be set arbitrarily 10Heating element: high-quality resistance wire 11Temperature: Good temperature control method 12Dimensions: Width 1350, Height 1450, Depth 1150mm 13Configure ZJ-3 and ZJ-6 piezoelectric testers |
||||||||||||||||||||
|
JKZC-YDZK03A Dielectric testertype Thin film dielectric and loss impedance tester (*****) |
JKZC-YDZK03A Dielectric testerThin film dielectric and loss impedance tester Keywords: dielectric constant, resonant frequencyFpElectromechanical coupling coefficientKeMechanical quality factorsQm JKZC-YDZK03A Dielectric testerType dielectric tester is a multifunctional dielectric tester that can test parameters including dielectric constant, dielectric loss, capacitance, etc., as well as measure resonant frequencyFs, anti resonant frequencyFpElectromechanical coupling coefficientKeMechanical quality factorsQm, maximum admittanceGmaxWaiting for material parameters, providing first-hand raw data for material research and testing, and providing integrated data graphs, is an important tool for higher education institutions, research institutes, and material research and production,At the same time, it can also be used in conjunction with high-temperature equipment to conduct high-temperature equipment testing.
1、 Main features: Automatic balancing technology bridge, high measurement accuracy 4End to Kelvin testing end, high measurement range accuracy Provide internal DC bias voltage-5V~+5V Optional internal ±40VBias voltage source Simplified Chinese and English operating languages Graded measurement, list scanning, drawing scanning, open circuit, short circuit, load correction and other functions Equipped with calculation function for conductivity σ · dielectric constant ε Save test data and test conditions(UDisk or internal) Draw and scan images directly onto the screenUDisk function Enhanced testing end protection function USBTheGPIBTheRS232TheLANWaiting for the upper computer to connect to the interface 2、 Main technical parameters 1Frequency:20HZ-1MHZ,5MHZ,10MHZ,15MHZ,30MHZ,50MHZmultiple options 2TheD33Test scope:0-6000PC/N(optionalZJ-3Precision piezoelectric coefficient tester) 5Basic accuracy:0.05% 6Test voltage level: 5mV—2Vrms 7Output impedance: 10Ω, 30Ω, 50Ω, 100Ω 8Test parameters:D33, capacitance, dielectric constant, resonant frequencyFs, anti resonant frequencyFpElectromechanical coupling coefficientKeMechanical quality factorsQm, maximum admittanceGmaxwait 9Number of channels:1通道 10Electrode: Double sided clamping probe 11Software: Automatically calculates and outputs data. The software can be designed according to experimental plans and measured throughCandDAutomatically complete the curve of dielectric constant and dielectric loss with multidimensional changes in frequency, voltage, and bias voltage. |
||||||||||||||||||||
|
PDMS-100type piezoelectric material friction nano Generator testing system (*****) |
PDMS-100Testing System for Friction Nano Generator of Piezoelectric Materials Keywords: piezoelectric, friction, nano, power generation PDMS-100The piezoelectric material friction nanogenerator testing system utilizes the coupling of frictional electrification effect and electrostatic induction effect to convert tiny mechanical energy into electrical energy. This is a new technology with output performance and advantages. It does not require magnets or coils, and uses lightweight, low-density, and inexpensive polymer materials in its production.PDMS-100The invention of frictional nanogenerators using piezoelectric materials is a milestone discovery in the field of mechanical energy generation and self driving systems, providing a new mode for effectively collecting mechanical energy. Main technical parameters: 1Sampling rate50k/sContinuously adjustable. 2Resolution16bit 3Input impedance:1GΩ 4Input bias current:+200pA 5Voltage range:10MV-200V 6Current range:20nA-20mA 7Resistance range:10mΩ-200GΩ 1. Input voltage:220VSingle-phase alternating current; 2. Torque:1.2 Cow rice; 3. Effective running length:300mmHigh precision belt transmission control; 4. 定位精度:0.06mmStep accuracy:0.0086mm 5. Maximum operating speed:300mm/s; 6. Control method: Computer program control 7. Pressure sensor: Range:0~100NAccuracy:+/- 0.1N 8.DAQData Collection Card: SupportsNIComplete series of collection cards, please refer to the specific specifications for detailsNI(as:USB 6002,6003wait), customizable development 9. Breadboard optical platform size:long600mm, wide300mm, thick13mm 10.frequency0-5HZ |
||||||||||||||||||||
|
FTWQ-50small flexible bend test system (*****) |
FTWQ-50Small flexible bending testing system The emergence of flexible electronics has provided a new direction for the development of classical electronics and triggered the emergence of new forms of electronic devices. However, in the process of electronic materials and devices transitioning from rigid to flexible, traditional rigid testing methods become inadequate, and matching flexible testing systems become essential for promoting the development of the flexible electronics industry. In the testing process of flexible electronic materials and devices, especially in the early stages of development and verification, develop a high degree of freedom modular flexible material and device testing system,It is of great significance to improve development verification efficiency and reduce testing costs. Suitable for precision stretching of small area films and devices/Bending test. Product Features: Complies with:satisfyGB/T 38001.61-2019Flexible Display Devices61part:Mechanical stress testing method; Product Features: Integrated design, test bench, small size, small footprint Easy to operate, one click operation, can stretch continuously multiple times Capable of handling various environments, such as glove boxes and laboratories Million consecutive tests, easy to operate, no training required;Small spaces such as exhibition booths and testing centers Scope of application: Suitable for flexible tensile testing of small area flexible films and flexible devices; Flexible electronic teaching machine, flexible electronic display machine. Scope of Application/ APPLICATION Suitable for flexible testing of small area flexible films and flexible devices Technical Specifications bend radius(mm):0-50 Sample width(ml,):0-50.0 sample thickness(mm):0-4.0 Bending speed(mm/s):0-60.0 precision(mm):0.05 weight(kg):10 power supplyAC(100-200V 50Hz/60Hz) Transmission ratio:1:1 power(W):200 Overall dimensions(mm):410*250*280 It is possible to configure a resistance meter for testing voltage, current, and other items Maximum voltage:64V, Rated current:8A voltage:1mV. current:1MA Voltage and current per second:50/25/10/5/1time adjustable:0.05%+3Less than one word30PPM Voltage reference:1000hour25PPM, Voltage divider resistor:rated power1000hour+0.05%,Current sensing resistor:rated power1000hour+0.5% The header power supply is isolated, and the positive and negative poles of the measurement channel are connected in reverse without burning, the input and output are connected in reverse without burning, and both the positive and negative poles and input and output are connected in reverse without burning Real time monitoring of voltage and current data acquisition software |
||||||||||||||||||||
|
FTLS-100 small flexible stretch test system (*****) |
FTLS-100Small flexible tensile testing system FTLS-100The small-sized flexible tensile testing system is an application forSuitable for flexible testing of small area flexible films and flexible devices;Flexible electronic teaching machine, flexible electronic display machine. satisfyGB/T 38001.61-2019Flexible Display Devices6-1Part: Mechanical stress testing methods; Million consecutive tests, easy to operate, no need for training; Compact in size, suitable for exhibition booths, testing centers, glove boxes, laboratories, etc. Complies with:satisfyGB/T 38001.61-2019Flexible Display Devices61part:Mechanical stress testing method; Product Features: Integrated design, test bench, small size, small footprint Easy to operate, one click operation, can stretch continuously multiple times Capable of handling various environments, such as glove boxes and laboratories Million consecutive tests, easy to operate, no training required;Small spaces such as exhibition booths and testing centers Scope of application: Suitable for flexible tensile testing of small area flexible films and flexible devices; Flexible electronic teaching machine, flexible electronic display machine. Technical Specifications: Test length(mm):0-100.0; Test width(mm):0-50.0 sample thickness(mm):0-4.0 Maximum operating speed(mm/s):0-60.0 precision(mm):0.05 weight(kg):10 power supplyAC(100-200V 50Hz/60Hz) Transmission ratio:1: 1 Power:200w Overall dimensions(mm):410*260*215 Maximum voltage:64V, Rated current:8A voltage:1mV. current:1MA Voltage and current per second:50/25/10/5/1time adjustable:0.05%+3Less than one word30PPM Voltage reference:1000hour25PPM, Voltage divider resistor:rated power1000hour+0.05%,Current sensing resistor:rated power1000hour+0.5% The header power supply is isolated, and the positive and negative poles of the measurement channel are connected in reverse without burning, the input and output are connected in reverse without burning, and both the positive and negative poles and input and output are connected in reverse without burning Real time monitoring of voltage and current data acquisition software |
||||||||||||||||||||
|
FTZD - 120small flexible fold test system (*****) |
FTZD - 120Small flexible folding testing system The emergence of flexible electronics has provided a new direction for the development of classical electronics and triggered the emergence of new forms of electronic devices. However, in the process of electronic materials and devices transitioning from rigid to flexible, traditional rigid testing methods become inadequate, and matching flexible testing systems become essential for promoting the development of the flexible electronics industry. In the testing process of flexible electronic materials and devices, especially in the initial stage of development and verification of flexible electronic materials and devices,development-A modular flexible material and device testing system with high degree of freedom,It is of great significance to improve development verification efficiency and reduce testing costs. Product Features [1]satisfyGB/T 38001.61-2019Flexible Display Devices6-1part:Mechanical stress testing method; [2]Ten thousand consecutive tests, easy to operate, no need for training; [3]Compact in size, suitable for exhibition booths, glove boxes in testing centers, laboratories, etc. Scope of application: Suitable for flexible testing of small area flexible films and flexible devices; Flexible electronic teaching machine, flexible electronic display machine. Highlight: Compact size; Flexible electronic teaching machines and display machines. Technical Specifications: sample size(mm):Max (50*120) sample thickness(mm):0-1.0 Folding angle(°):0- 180.0 Folding angle(°):0-90.0 Folding radius(mm):0.5- -5.0 Folding speed(/s):0-90.0 weight(Kg):10 power supplyAC(100-200V 50Hz/60Hz) Transmission ratio:1: 1 Power:200W Maximum voltage:64V, Rated current:8A voltage:1mV. current:1MA Voltage and current per second:50/25/10/5/1time adjustable:0.05%+3Less than one word30PPM Voltage reference:1000hour25PPM, Voltage divider resistor:rated power1000hour+0.05%,Current sensing resistor:rated power1000hour+0.5% The header power supply is isolated, and the positive and negative poles of the measurement channel are connected in reverse without burning, the input and output are connected in reverse without burning, and both the positive and negative poles and input and output are connected in reverse without burning Real time monitoring of voltage and current data acquisition software |