E-mail
huijuan_sun@bct-tech.com
-
Phone
18610719775
-
Address
Building 1, Courtyard 6, Anqing Street, Airport Industrial Zone B, Shunyi District, Beijing
Beijing Boside Technology Co., Ltd
huijuan_sun@bct-tech.com
18610719775
Building 1, Courtyard 6, Anqing Street, Airport Industrial Zone B, Shunyi District, Beijing
Although the concentration of fluorinated greenhouse gases such as CFCs, HCFCs, HFCs, and PFCs in the atmosphere is lower than that of CO2, their global warming potential (GWP) is several hundred to tens of thousands of times that of CO2, accounting for 11% of greenhouse gas radiation intensity. They play an important role in global warming and require strengthened control.
In order to better fulfill international conventions such as the Montreal Protocol, the United Nations Framework Convention on Climate Change, and the Kyoto Protocol, and to understand the actual situation in China, the Ministry of Ecology and Environment has requested to carry out monitoring of fluorine-containing greenhouse gases in documents such as the Carbon Monitoring and Assessment Pilot Work Plan. The monitoring points include various types such as regional background points, urban emission points, and urban background points, with concentration levels distributed in a wide range of ppt ppm. The detection limit, accuracy, and pollution resistance of the analysis system have been proposedvery highrequirement
To meet the national demand for monitoring and controlling fluorinated greenhouse gases, Beijing Boside Technology, based on years of VOCs monitoring and analysis experience, has launched the BCT 990F high-precision fluorinated greenhouse gas pre concentration system after two years of research and optimization.
Applicable scenarios
The BCT 990F high-precision fluorine-containing greenhouse gas pre concentration system has the advantages of low detection limit, high accuracy, high pollution resistance, and wide detection concentration range, and is suitable for

standard basis
Technical specifications for manual monitoring of ozone depleting substances and fluorinated greenhouse gases in ambient air
Detection Principle
The 990F pre concentrator adopts a dedicated four stage trap design to remove impurities while enriching and concentrating organic halides such as ODS and fluorinated greenhouse gases in the sample. One injection can accurately detect more than 40 substances, with advantages such as low detection limit, high accuracy, strong pollution resistance, and wide detection concentration range.

Instrument Features

instrument performance
1.Test spectrum

2. Monitoring accuracy

3. detection limit
The detection limits of all components are average<0.1ppt
4. monitoring scope
0.1ppt~ppm