Welcome Customer !

Membership

Help

Beijing Beidouxing Technology Co., Ltd
Custom manufacturer

Main Products:

instrumentb2b>Download Materials>Odor detector/environmental pollutant detector
Download

Beijing Beidouxing Technology Co., Ltd

  • E-mail

    674338455@qq.com

  • Phone

    18611900152

  • Address

    18 Qinghe Anningzhuang East Road, Haidian District, Beijing

Contact Now
Odor detector/environmental pollutant detector
Date: 2017-09-25Read: 0

PAir2000-EFF portable environmental atmospheric odor pollutantsdetectionceremony

Big DipperpAir2000-EFFportableEnvironmental atmospheric odor pollutantsdetectionceremony, integrating the wisdom of several generations of Beidou experts from the Chinese Academy of Sciences over the past three decades, and integrating all practical and reliable gas sensors in the world by studying different gas detection and sensing technologiesCatalytic combustion method, semiconductor methodPID photoionization method and other methods are used to establish a system that can adapt to various application environments,By optimizing different gas combinations and interference factors,At the same time, it can meet the requirements of on-site, high-resolution gas detection combination mode. After more than 20 years of continuous exploration, testing and technological upgrading, it has formed six product series for odor gas emission detection, which are targeted for various complex environmental gas detection.

pAir2000-EFFportableEnvironmental atmospheric odor pollutantsdetectionceremonyRefer toNational Standard of the People's Republic of China GB14554-93《Emission standards for odor pollutants》Requirement, specifically forEnvironmental odor pollutionA gas emission detection analyzer designed with 4 to 23 built-in basic gas detection sensors, each capable of detecting specific odorous gases. The series of 6 models of instruments not only meet the gas pollution detection requirements of national standards, but also meet the recent regulations of local governments《Local pollutant emission standards》Requirements and characteristics of industrial gas pollution source emissions.

PAir2000-EFF portable environmental atmospheric odor pollutantsdetectionceremonyThe design concept is to establish a platform that caters to various on-site environments,Optimize different gas combinations and interference factors,Satisfying on-site detection and high-resolution gas detection combination mode, after more than 20 years of continuous exploration, experimentation, and technological upgrades, six product series have been formed, includingpAir2000-EFF-A型Yes, universalodor pollutantsdetectionInstrument;pAir2000-EFF-Type BIt meets the requirements of this seriesNational Standard《Emission standards for odor pollutants》Multi parameter gas detector for testing requirements,pAir2000-EFF-C is specifically designed forindustrial production、sewage treatment plant、Biopharmaceuticals and ChemicalsThe detection parameters for pollution source emissions, including methane and chlorine, meet the characteristics and requirements of industrial gas emissions;

*The application of module processing intelligent system and cross interference gas neural network correction mode analysis technology,To achieve real-time correction and supplementation

Compensation, obtaining reliable and accurate test results,This provides a reliable guarantee for the resolution of the instrument.The multi-functional integrated design of one machine also saves financial and manpower resources for society, and improves detection efficiency.

pAir2000-EFFportableEnvironmental atmospheric odor pollutantsdetectionceremonyIt is widely used in industries such as petrochemicals, chemicals, wood, paper, environmental protection agencies, and environmental colleges. Its speed, convenience, reliability, and durability have been rated as competitive domestic gas detectors by users.

Advantages of Instrument Technology

  • The standard built-in basic gas detection sensors range from 4 to 23,Each sensor responds to different gases.

satisfyNational StandardplaceEmission standards for odor pollutants》Requirement.

  • Conventional setup includes 6 channels for gas and 1 channel for temperature testing and 1 channel for humidity testing.
  • Support DKA (dual standard method) standard sample or substitute calibration, as well as single point pure inert gas calibration.
  • Providing cross interference gas neural network correction mode analysis technology has solved the problem of cross interference in gas detection.
  • The multi-functional integrated design of one machine saves users financial and human resources, and improves detection efficiency.

【Instrument functions】

  • The gas sensor adoptsElectrochemical method, gas sensing method, infrared methodCatalytic combustion method, semiconductor methodSensing technologies such as PID photoionization method.
  • You can choose according to the actual situationgasdetection parameters,Simultaneously detecting multiple gases on one instrument.
  • Equipped with printing、performableon-siteLaboratory testing requires.
  • Pump sampling and sampling.
  • The sensor operates in real-time and continuously detects the working mode.
  • Power undervoltage and power failure alarm.
  • Quickly detect parameters and temperature values, and perform temperature correction and cross correction.
  • Inert gas software zeroing, standard sample or substitute calibration.
  • All operation keyboard settings, window prompts.
  • On site LCD 4 × 16 character rotating display of multiple environmental parameters.
  • The RS232/RS485 communication interface supports serial communication and can be connected to a computer.
  • Users can also calibrate or calibrate themselves.

【Technical Specifications】

  • Response time:<10ms
  • Long term stability: ± 10%/year (generally)
  • Host resolution: 0.1% FS
  • Sensor accuracy: ± 1-2% reading (general)
  • Probe response time:<3mins (T90)
  • Instrument usage environment: Temperature: -10℃~60℃Humidity: 10%~90% R (no condensation)
  • Instrument storage environment: Temperature: 0℃~4℃Humidity: 10%~80% R (no condensation)
  • Probe sampling requirements: Temperature: 0~40℃Pressure:<1.1 kgf/cm2
  • Instrument power supply: 12V rechargeable battery
  • Instrument size: 400 × 300 × 200mm
  • Instrument weight: 4.5Kg

【Typical Instrumentapplication】

  • pAir2000-EFF-Type A configuration parameters (applicable to general type)odor pollutantsTesting)
  • pAir2000-EFF-B-type configuration parameters (applicable)National standard GB14554-93《Emission standards for odor pollutants》Requirement)
  • pAir2000-EFF-C-type configuration parameters (applicable)industrial production、sewage treatment plant、Biopharmaceuticals and ChemicalsPollution source emissions
  • pAir2000-EFF-D-type configuration parameters (applicable to solid waste landfill pollution source emissions)
  • pAir2000-EFF-E-type configuration parameters (applicable for air pollutant emission gas detection)
  • pAir2000-EFF-F-type configuration parameters (applicable to expansion instruments, with the option to add gas)

pAir2000-EFF-Type A configuration parameters(Applicable to universal type)odor pollutantsTesting)

No

Main measured gas

Gas parameters

Testing Scope

1

Ammonia and low molecular weight amines

NH3

0.5-50/200ppm

2

Hydrogen sulfide and sulfide

H2S

0.3-100mg/m3

3

Thiols and thioethers

CH3SH

0.5-50mg/Nm3

4

Volatile organic compounds

EVOC

0.1-100ppm

5

Odor concentration

ODU

0-500 dimensionless

pAir2000-EFF-B-type configuration parameters(Applicable)national standardGB14554-93《Emission standards for odor pollutants》Requirement)

serial number

Main measured gas

range

Zui low lower limit

1

Ammonia NH3

0~100 ppm

0.1ppm

2

Hydrogen sulfide H2S

0~100 ppm

0.1ppm

3

Styrene C8H8

3.0~19 ppm

0.02ppm

4

*Amine (CH3)3N

0~5 ppm

0.005ppm

5

Methyl mercaptan CH3SH

0~14 ppm

0.01ppm

6

Sulfide (CH)3)2S

0~300ppm

0.3ppm

7

Carbon disulfide CS2

0~100 ppm

0.1ppm

8

Dimethyl disulfide (CH)3)2S2

0.03~30ppm

0.03ppm

9

Organic volatile gas TVOC

0-200ppm

0.2ppm

10

Odor concentration

0-10000

10

pAir2000-EFF-C-type configuration parameters(Applicable)sewage treatment plant、BiopharmaceuticalstransformworkFactory pollution source emissions)

serial number

gas

Main measured gas

sensor

measurement range

1

ammonia

NH3

electrochemistry

0.75-75 mg/m3

2

hydrogen sulfide

H2S

electrochemistry

0.15-75/750 mg/m3

3

chlorine gas

CL2

electrochemistry

0.05-5/50ppm

4

methane

CH4

infrared

0-4%;

5

Odor concentration

ODU

0-500 dimensionless

pAir2000-EFF-D-type configuration parameters (applicable)Pollution source emissions from solid waste landfill sites)

No.

Main measured gas

Gas parameters

Testing Scope

1

Ammonia and low molecular weight amines

NH3

0.5-50/200ppm

2

Hydrogen sulfide and sulfide

H2S

0.3-100mg/m3

3

Thiols and thioethers

CH3SH

0.5-50mg/Nm3

4

hydrogen

H2

0-1%

5

oxygen

O2

0-25%

6

carbon dioxide

CO2

050%;

55-100%;

7

carbon monoxide

CO

02000ppm

8

organic gas

VOC

0-5% 5-100%

9

Non methane organic gas

NMOCs

10

Chlorofluorocarbons

CFC

0-3000ppm

11

Other organic toxic gases

EVOC

0.1-100ppm

12

Other toxic gases

C6H5CH3

0.1-30ppm

13

Odor concentration

ODU

10-10000

pAir2000-EFF-E-type configuration parameters (applicable for air pollutant emission gas detection)

No

Gas name

Gas parameters

Testing Scope

1

temperature

T

-40-100℃

2

humidity

RH

0-99%RH

3

flow velocity

Air velocity

0.01-20m/s

4

sulfur dioxide

SO2

0.025-10/100ppm

5

hydrogen sulfide

H2S

0.1-50/500ppm

6

carbon monoxide

CO

0.1-500/1000ppm

7

carbon dioxide

CO2

2-2000ppm

8

nitrogen dioxide

NO2

0.02-10/100ppm

9

nitric oxide

NO

0.5-100/300ppm

11

ammonia

NH3

1-100ppm

12

Volatile organic gases

VOCs

0.1-100ppm

13

ozone

O3

0.02-2/5ppm

14

Total suspended particulate matter

TSP

0.01-2/20mg/M3

14

PM10

PM10

0.01-2/20mg/M3

14

PM2.5

PM2.5

0.01-100mg/M3

15

hydrogen fluoride

HF

0.25-10ppm

16

Benzo[a]pyrene

B[a]P

0.015-1.5mg/NM3

17

formaldehyde

CH2O

0.05-10.0ppm

18

benzene

C6H6

0.03-30ppm

19

toluene

C7H8

0.04-50ppm

20

xylene

C8H10

0.04-50ppm

21

radon

Rn

0-1000Bq/NM3

22

Total Bacterial Count

TNB

0-25000CFU/NM3

23

lead

Pb

24

noise

Noise

35-130dB

25

methanol

CH3OH

0.05-50ppm

26

chlorine gas

Cl2

0.05-5ppm

27

Odor concentration

ODU

10-10000

pAir2000-EFF-F-type configuration parameters (applicable to expansion instruments, with the option to add gas)

No

Gas name

Gas parameters

1

sulfur dioxide

SO2,

2

hydrogen sulfide

H2S,

3

nitrogen dioxide

NO2,

4

nitrogen dioxide

NO2,

5

nitric oxide

NO,

6

nitric oxide

NO,

7

carbon monoxide

CO,

8

carbon dioxide

CO2

9

Air Quality Index

AQI

10

Volatile organic gases

TVOC

11

ozone

O3,

12

ammonia

NH3,

13

ammonia

NH3,

14

fluoride ion

F-

15

Fluorine gas

F2

16

chloride ion

Cl-

17

chlorine gas

Cl2

18

Cyanide radical

CN-

19

formaldehyde

CH2O

20

carbon disulfide

CS2

21

Methanethiol

CH3SH

22

Methanethiol

CH3SH

23

Disulfide dimethyl

C2H6S2

Complete set of components

Instrument standard configuration

pAir2000-EFFMain analyzer

temperature probe

Humidity probe

Standard gas sensor

rechargeable battery

charger

Sampling gun

Aluminum alloy instrument box

Optional accessories

mini printer

Expand gas sensors

Pipe joint fittings

Electric sampling pump

Electric sampling pump

Electric sampling pump

Electric sampling pump

Dissolved gas testing kit

pressure reducer

Stabilizer

Electronic thermostat

filter

flow meter

electronic flow meter

Instrument user:

PetroChina Jinxi Petrochemical Plant, Ningbo Asia Pulp and Paper Industry, Keno (Beijing) Wood Industry Co., Ltd., Jinhu Tire (Tianjin) Co., LtdCivil Aviation University of China, China Western Cement Co., LtdYaobai Special Cement GroupDalian Nationalities UniversityWuhu Solid Waste Treatment Project, etc

sewage treatment plantEmissions of odorous gases/Solid waste landfill odorous gases/Urban waste odorous gases/biopharmaceuticalEmissions of odorous gases/chemicalsworkFactory emissions of foul smelling gases/Municipal sewage treatment plantEmissions of odorous gases/industrial productionEmissions of odorous gases

If interested, please contact the Beijing Beidouxing Industrial Chemistry Research Institute: