Medical centrifugeBy utilizing the centrifugal force generated by the high-speed rotation of the rotor, particles in the liquid are forced to overcome diffusion and accelerate settling speed, thereby separating substances with different settling coefficients and buoyancy densities from the sample.
Advantage:
High separation efficiency: The strong centrifugal force generated by high-speed rotation can quickly achieve the separation of different density components, which is tens of times more efficient than traditional separation methods.
Strong sample compatibility: Suitable for various biological samples such as blood, cells, tissue fluids, nucleic acids, proteins, etc., supporting multiple containers such as centrifuge tubes, centrifuge bottles, enzyme-linked immunosorbent assay plates, etc.
Safe and convenient operation: Equipped with an intelligent control system, it can preset parameters such as speed, time, temperature, etc., and start running with one click; The safety protection device is comprehensive to avoid risks such as rotor imbalance and sample leakage during the centrifugation process.
Compliant with medical standards: The contact parts between the body and the sample are made of medical grade stainless steel or corrosion-resistant materials, which are easy to clean and disinfect and comply with relevant regulations.
Medical centrifugeDaily operating standards:
Sample balance: Before centrifugation, it is necessary to ensure that the weight difference of symmetrically placed samples is ≤ 0.1 g to avoid equipment vibration, damage, and even safety accidents caused by rotor imbalance.
Parameter setting: Set appropriate speed, time, and temperature according to the sample type, and strictly prohibit exceeding the maximum rated speed of the rotor. The refrigeration machine model needs to be pre cooled in advance.
Loading and unloading: Handle the sample gently when loading to avoid damaging the centrifuge tube; After centrifugation is complete, wait for the rotor to come to a complete stop before opening the cabin door. Forced braking is prohibited.
Cleaning and disinfection: After each use, wipe the rotor and centrifuge chamber with an alcohol swab. If there is a sample leak, immediately clean and disinfect to prevent cross contamination.