E-mail
zhsdyq@163.com
-
Phone
13699145010
-
Address
No.1 Economic and Technological Development Zone, Fangshan District, Beijing
Beijing AVIC Times Instrument Equipment Co., Ltd
zhsdyq@163.com
13699145010
No.1 Economic and Technological Development Zone, Fangshan District, Beijing
11.23,20200
ZJC series microcomputer controlled breakdown voltage tester product introduction (20KV-150KV)
1purpose
Mainly suitable for testing the breakdown strength and withstand time of solid insulation materials such as resins and adhesives, impregnated fiber products, mica and its products, plastic composite products, ceramics and glass under power frequency voltage or DC voltage; This instrument is computer-controlled and can quickly and accurately collect, process, access, display, and print various data during the experimental process.
2. According to the standard
The instrument is manufactured according to the requirements for breakdown voltage in the following standards
1. GB1408.1-2006 "Test Methods for Electrical Strength of Insulation Materials"
2. GB1408.2-2006 "Test Methods for Electrical Strength of Insulation Materials Part 2: Additional Requirements for Application of DC Voltage Test"
3. GB/T1695-2005 "Determination method for power frequency breakdown voltage strength and withstand voltage of vulcanized rubber"
4. ASTM D149 "Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulation Materials at Industrial Power Supply Frequency"
5. GB/T3333: Test method for power frequency voltage breakdown of cable paper;
6. GB/T12656: Test method for power frequency voltage breakdown of capacitor paper
7. HG/T3330: Determination method for breakdown strength of insulation paint film.
3. Function:
1. During the experiment, the experimental curve can be dynamically drawn, and the experimental curve can be overlaid and compared with multiple colors.
2. Can edit and modify experimental data, flexible and applicable;
3. The experimental conditions and test results can be automatically stored;
4. The format of the test report is flexible and adaptable to meet the different needs of different users;
5. The validity of curve data in a set of experiments can be manually selected;
6. The experimental result data can be imported into Excel and edited in WORD documents;
7. The overcurrent protection device has sufficient sensitivity to ensure that the power is cut off within 0.1 seconds when the sample breaks down;
8. Durability of instrument operation: The instrument can operate continuously without the need for periodic shutdowns to protect it. .
3、 Main technical requirements: (Parameters can be modified or customized according to usage requirements)
Project |
ZJC-20KV |
ZJC-50KV |
ZJC-100KV |
ZJC-150KV |
||
input voltage |
220V 50HZ |
380V 50HZ |
||||
Voltage measurement range |
AC/DC 0-20KV |
AC/DC 0-50KV |
AC/DC 0-100KV |
AC/DC 0-150KV |
||
Electrical capacity (power) |
2KVA |
5KVA |
10KVA |
15KVA |
||
overcurrent protection |
0-50mA |
0-150mA |
||||
pressure rate |
0.1KV/S-5KV/S |
0.5KV/S-10KV/S |
||||
Experimental method |
AC/DC test: 1. Constant voltage boost 2. Step by step boost 3. Voltage withstand test |
|||||
Measurement error of AC/DC voltage |
2%≤ |
|||||
Current measurement error |
2%≤ |
|||||
Pressure resistance time |
0-4H (German standard 8H or 15H) or any setting |
|||||
Instrument dimensions (length, width, height) |
700*800*1400mm |
1200*1100*1500mm |
2100*1500*2100mm |
|||
Host rescheduling |
150kg |
300KG |
500kg |
|||
Level 9 security protection |
Overvoltage, test overcurrent, test short circuit, safety door opening, software misoperation, zero voltage reset, discharge at the end of the test, independent protective grounding, electromagnetic discharge after the test is completed |
|||||