Performance indicators of natural gas composition analyzer:
| measurement range | % , ppm |
| Operating temperature | -10°to +50°C |
| attachment | Low carbon steel box with front safety door(Polyurethane sealing) Dip coating primer, texture coating spray coating industrial use10“touch display screen |
| Installation method | Wall mounted (including installation bracket and bolt kit) |
| size | W = 600mm, H = 600mm, D = 350mm |
| weight | 25kg |
| power supply | 110V/220V, 50/60HzPower:1440W |
| detector | Thermal conductivity detector (other detectors are optional) |
| Gas pipeline | 1/8”stainless steel pipe Other corrosion-resistant materials can also be provided |
| joint | 1/8”stainless steelSwagelokcard holder |
| valve | stainless steel/Hastelloy rotary valve or diaphragm valve 10 through/ 8through/ 6through/ 4Tong (depending on the application) fromTrendVision PROWorkstation software controls and drives the action of the air valve long lifespan |
| chromatographic column | Filled column, micro filled column, capillary column Independent temperature controlled column box On site renewable energy |
| Sample gas flow rate | 10 - 500 mL/min(recommend200 mL / minTraffic) |
| sensitivity | < 5 ppm |
| zero drift | Automatically reset to zero every cycle |
| Span Drift | 1ppmexceed48 hour(ppmapplication) |
| repetitiveness | Good repeatability benefits fromTrendVisionEquipped with automatic calibration function |
| linear | 104 |
| call the police | High and low alarm outputs Common fault alarms Sample gas, carrier gas, and auxiliary gas alarm Temperature Alarm Maintenance status mode alarm |
| computer software/hardware | Embedded industrial computer- 24bitADCAnd related hardware In®Celeron®(Four core,2.0 GHz),4GB DDR3L SDRAM,128Gb SSDstorage industrial use10“Touch capacitive display screen embeddedWindowsOperating System English AGC Trend Vision PROChromatography software Other languages will be released soon |
| Enter options | 0-10VAnalog input(8) 4-20mAAnalog input(8) Digital input(4) |
| output option | 4-20mAanalog output Profibus / Modbusinterface RS232 / RS485 TCP / IP(Ethernet) Status relay Power failure indication |
| test | Testing the aging of electronic components under simulated conditions The system's condition can be monitored in the early, middle, and later stages of testing insulation test/Withstand Voltage Test Voltage stability test |
| certification | CEcertification ATEXCertification availableNovaPRO PGCChromatographic system ISO 9001:2015certification |